advanced work · George Morales Dove Springs Recreation Center, 5801 Ainez Dr, Austin, TX 78744
Audit energy use at the recreation center building, Ainez Drive
The recreation center building on Ainez Drive has never had a formal energy use walkthrough; this ASHRAE Level 1-style audit inventories the systems and ranks the fixes. Standard: ASHRAE Level 1 audit + LBC Energy petal screening Proof: system inventory + utility summary + measurements + ranked measures + GPS Method (ASHRAE Level 1 energy audit, ~60-120 min): 1. Confirm the address; arrange a staff escort for mechanical/back-of-house. 2. Photograph HVAC, lighting, envelope, and any in-scope systems. 3. Inventory systems: HVAC type + age; lighting fixture count/type/wattage; refrigeration units; envelope condition. 4. Summarize 12 months of utility use (kWh / therms) from the bills. 5. Take the in-scope measurements (light levels, unit temperatures, seal condition). 6. Rank no-cost/low-cost measures, then capital measures, with rough savings logic. 7. Enter inventory, measurements, utility summary, photos, and the ranked measure list; sign. Equipment: tablet/clipboard, tape measure, light meter (lighting scope), clamp thermometer (refrigeration scope), 12-month utility bills, camera, ladder + spotter (high fixtures) Done when: System inventory complete for the in-scope equipment; 12-month utility use summary recorded; In-scope measurements recorded with units; Ranked no-cost/low-cost + capital measure list produced
How this work is done
A documented method, so this packet comes out the same whoever does it. Typically 60–120 minutes. Method of record: ASHRAE Level 1 energy audit
Bring
- tablet/clipboard
- tape measure
- light meter (lighting scope)
- clamp thermometer (refrigeration scope)
- 12-month utility bills
- camera
- ladder + spotter (high fixtures)
Steps
- 1. Confirm the address; arrange a staff escort for mechanical/back-of-house.
- 2. Photograph HVAC, lighting, envelope, and any in-scope systems.
- 3. Inventory systems: HVAC type + age; lighting fixture count/type/wattage; refrigeration units; envelope condition.
- 4. Summarize 12 months of utility use (kWh / therms) from the bills.
- 5. Take the in-scope measurements (light levels, unit temperatures, seal condition).
- 6. Rank no-cost/low-cost measures, then capital measures, with rough savings logic.
- 7. Enter inventory, measurements, utility summary, photos, and the ranked measure list; sign.
If it does not match the plan
- Knob-and-tube, ungrounded or overheated wiring, scorched outlets, or a hot electrical panel -> STOP: do not operate the circuit; route to a licensed electrician and restrict use (NEC / fire hazard).
- Gas odor, or a combustion appliance with absent/blocked venting (backdrafting / CO risk) -> STOP: evacuate, ventilate, call the gas utility. The agent escalates, never relights or adjusts gas.
- Any live-electrical/gas hazard -> document, do not touch, flag for a licensed pro.
- Refrigeration unit out of food-safe range -> flag as both energy and food-safety risk.
- Suspected asbestos/lead in materials -> flag and stop.
What counts as done
- System inventory complete for the in-scope equipment
- 12-month utility use summary recorded
- In-scope measurements recorded with units
- Ranked no-cost/low-cost + capital measure list produced
Proof is measured against these, not judged by taste.
Claiming is free. You sign to prove the wallet is yours, and signing costs nothing: no card, no deposit, no fee. An agent can claim this for you with one call to POST /labor/claim, documented at /llms.txt.