intermediate work · 700 block of Hague Ave, Hilltop, Columbus OH 43223 (residential)

Run a blower-door infiltration test on a home, the 700 block of Hague Ave, Hilltop

Nobody on the 700 block of Hague Ave, Hilltop has a number for how leaky their home actually is; a calibrated blower-door test turns "it's drafty" into a CFM50 reading and a ranked list of the home's worst air-leak paths for the tightening crew to target. Standard: Ohio Development Services Agency Home Weatherization Assistance Program (HWAP) — the state pass-through of the DOE Weatherization Assistance Program's cold-climate field protocol: blower-door-directed air sealing toward a CFM50 infiltration target, attic insulation to R-49 / wall cavity to R-13, and mandatory pre/post combustion-safety (CO/backdraft) testing before any tightening closes out. Under the LBC Energy petal; SDG 7.3 (energy efficiency) + SDG 13.1 (climate resilience — Columbus winter heating-degree-days). Proof: Photo of the blower-door setup in the entry door frame + CFM50 reading + Photos of each identified top infiltration path + Combustion-safety baseline reading (CO ambient, spillage check) + ranked leak list handed to the occupant Method (Ohio Development Services Agency Home Weatherization Assistance Program (HWAP) — the state pass-through of the DOE Weatherization Assistance Program's cold-climate field protocol: blower-door-directed air sealing toward a CFM50 infiltration target, attic insulation to R-49 / wall cavity to R-13, and mandatory pre/post combustion-safety (CO/backdraft) testing before any tightening closes out. Under the LBC Energy petal; SDG 7.3 (energy efficiency) + SDG 13.1 (climate resilience — Columbus winter heating-degree-days).): 1. Walk the home with the occupant, note combustion appliances present (furnace, water heater, gas range) and photograph each nameplate. 2. Set up the calibrated blower-door fan in the main entry door frame per manufacturer instructions and depressurize the home to the test pressure. 3. Record the CFM50 reading, then walk the home with a smoke pencil/hand to find and photograph the top infiltration paths (rim joist, attic hatch, penetrations, window/door perimeters). 4. Run the baseline combustion-safety check (CO ambient reading, spillage check at draft hoods) with the blower door off before closing out. 5. Deliver the one-page readiness sheet: CFM50 result, ranked leak list, and combustion-safety flag status, and photograph it handed to the occupant. Done when: Photo of the blower-door setup in the entry door frame + CFM50 reading + Photos of each identified top infiltration path + Combustion-safety baseline reading (CO ambient, spillage check) + ranked leak list handed to the occupant

Where
700 block of Hague Ave, Hilltop, Columbus OH 43223 (residential)
Pay
$90 proposed

This packet is not funded yet, so this figure is a proposed price and not money waiting in escrow. If a buyer funds it, approved proof settles that price onchain. If nobody funds it, approved proof earns provable credit toward the work instead of cash. You see which before you claim, never after.

Proof
Photo of the blower-door setup in the entry door frame + CFM50 reading + Photos of each identified top infiltration path + Combustion-safety baseline reading (CO ambient, spillage check) + ranked leak list handed to the occupant

This is exactly what gets it approved. Nothing settles without it.

Level
intermediate
Open until
2026-09-01

How this work is done

A documented method, so this packet comes out the same whoever does it. Typically 90–240 minutes. Method of record: Ohio Development Services Agency Home Weatherization Assistance Program (HWAP) — the state pass-through of the DOE Weatherization Assistance Program's cold-climate field protocol: blower-door-directed air sealing toward a CFM50 infiltration target, attic insulation to R-49 / wall cavity to R-13, and mandatory pre/post combustion-safety testing before any tightening closes out.

Bring

Steps

  1. 1. Walk the home with the occupant, note every combustion appliance present, and photograph each nameplate before any work begins.
  2. 2. Set up the calibrated blower door in the main entry and record the baseline CFM50 reading.
  3. 3. Trace and photograph the top infiltration paths with a smoke pencil (rim joist, attic hatch, penetrations, window/door perimeters).
  4. 4. Run the pre-tightening combustion-safety check (ambient CO reading, spillage test at draft hoods) with the blower door off; a failed check stops the job and routes to a licensed HVAC technician before any sealing.
  5. 5. Air-seal the ranked leak paths in order and bring attic insulation to R-49 / accessible wall cavity to R-13 per the HWAP job sheet, maintaining required soffit-to-ridge ventilation.
  6. 6. Re-run the blower-door test to confirm the new CFM50 result.
  7. 7. Run the mandatory post-tightening combustion-safety re-test; a failed re-test stops the job and routes to a licensed HVAC technician for venting correction before further sealing.
  8. 8. Photograph the finished insulation depth and the passed post-tightening combustion-safety check; enter before/after CFM50, materials used, and the combustion-safety result into the proof record; sign.