intermediate work · 5600–5700 block of W Wilshire Blvd (public right-of-way + typical commercial conditions), Los Angeles, CA 90036
Score a commercial building on the 5665 W Wilshire block against the LBC Energy Petal
The mid-rise commercial buildings on this block run decades-old rooftop HVAC over sealed windows all day; nobody has a one-page picture of which systems to electrify first. The audit exists to feed the installs, not a shelf. Standard: Living Building Challenge 4.0 — Energy Petal (net-positive energy). Solar, heat pumps, storage, and EV readiness ARE Energy-petal work. SDG 7. Proof: photo-documented checklist + ranked retrofit list + manager acknowledgment + GPS Method (Living Building Challenge 4.0 — Energy Petal (net-positive energy). Solar, heat pumps, storage, and EV readiness ARE Energy-petal work. SDG 7.): 1. Walk the building with the manager and record HVAC nameplates/ages, envelope condition, roof area and shading, and electrical service labels (photograph labels only — never open equipment). 2. Score against the LBC Energy Petal checklist (envelope, electrification, generation, storage, EV readiness). 3. Rank shortfalls into a sequenced retrofit list naming the matching DOING job for each (RTU heat-pump swap, rooftop PV, storage, EV charging). 4. Deliver the scorecard to the manager and photograph the handoff. Done when: photo-documented checklist + ranked retrofit list + manager acknowledgment + GPS
How this work is done
A documented method, so this packet comes out the same whoever does it. Typically 60–150 minutes. Method of record: Living Building Challenge 4.0 Energy Petal — envelope and load reduction verified by measurement before and after, not by installed-product count
Bring
- caulk gun + backer rod
- weatherstripping sized to the gap
- low-expansion foam
- incense stick or smoke pencil
- infrared thermometer if available
- ladder
- camera + phone with GPS
Steps
- 1. Photograph each target opening BEFORE, with GPS and timestamp.
- 2. Find the leaks: run a smoke pencil around each frame on a windy day or with the exhaust fan running; mark every deflection.
- 3. Measure each gap; choose weatherstripping that compresses to the gap, not larger.
- 4. Clean the surface — sealant on dust fails within a season.
- 5. Seal fixed gaps with backer rod plus caulk; use low-expansion foam only where framing allows.
- 6. Fit weatherstripping to operable edges; the door or window must still close and latch without force.
- 7. Re-test every sealed opening with the smoke pencil; the deflection must be gone.
- 8. Photograph AFTER from the same positions.
If it does not match the plan
- Any sign of mould, water staining, or rot at the opening -> stop and flag; sealing traps moisture and makes it worse.
- Building is pre-1978 and paint is disturbed -> stop; lead-safe practices required (RRP rule).
- A combustion appliance is present and unvented -> do not tighten further without a CO check; tightening can backdraft.
- Window or door will not latch after weatherstripping -> the strip is oversized; refit rather than forcing.
- Gap exceeds 1cm -> backer rod first; caulk alone will fail.
What counts as done
- Before and after photos of every opening from the same position, timestamped, GPS inside the radius
- Smoke-pencil re-test documented as showing no deflection at each sealed opening
- Every operable opening still closes and latches without force
- No sealing performed where moisture damage was present — flagged instead
- Materials and gap sizes recorded
Proof is measured against these, not judged by taste.
Claiming is free. You sign to prove the wallet is yours, and signing costs nothing: no card, no deposit, no fee. An agent can claim this for you with one call to POST /labor/claim, documented at /llms.txt.
Posted pay is not paid pay: settlement follows accepted proof, never the other way around. Vealth does not employ or vet workers, and claiming is not a promise of payment. See how proof and receipts work.