advanced work · 1300 block of Duxberry Ave, Linden, Columbus OH 43211 (residential)

Complete the blower-door-directed weatherization retrofit, the 1300 block of Duxberry Ave, Linden

The blower-door test on the 1300 block of Duxberry Ave, Linden named the home's worst leaks and confirmed it's safe to tighten; this is the HWAP-standard crew visit that actually closes those leaks and brings the attic/wall insulation up to the cold-climate target so the reading — and the winter heating bill — actually change. Standard: Ohio Development Services Agency Home Weatherization Assistance Program (HWAP) — the state pass-through of the DOE Weatherization Assistance Program's cold-climate field protocol: blower-door-directed air sealing toward a CFM50 infiltration target, attic insulation to R-49 / wall cavity to R-13, and mandatory pre/post combustion-safety (CO/backdraft) testing before any tightening closes out. Under the LBC Energy petal; SDG 7.3 (energy efficiency) + SDG 13.1 (climate resilience — Columbus winter heating-degree-days). Proof: Before/after CFM50 readings from the same blower-door setup + Photos of each sealed leak path and the finished attic/wall insulation depth + Post-tightening combustion-safety (CO/backdraft) check result, passed Method (Ohio Development Services Agency Home Weatherization Assistance Program (HWAP) — the state pass-through of the DOE Weatherization Assistance Program's cold-climate field protocol: blower-door-directed air sealing toward a CFM50 infiltration target, attic insulation to R-49 / wall cavity to R-13, and mandatory pre/post combustion-safety (CO/backdraft) testing before any tightening closes out. Under the LBC Energy petal; SDG 7.3 (energy efficiency) + SDG 13.1 (climate resilience — Columbus winter heating-degree-days).): 1. Review the prior blower-door readiness sheet and confirm the ranked leak list and combustion-safety clearance before starting. 2. Air-seal the ranked leak paths in order (rim joist, top-plate penetrations, attic hatch, duct boots) with foam/caulk per DOE WAP practice; photograph each sealed location. 3. Bring attic insulation to R-49 and any accessible wall cavity to R-13 per the HWAP job sheet, maintaining required soffit-to-ridge ventilation. 4. Re-run the blower-door test to confirm the new CFM50 result and re-run the post-tightening combustion-safety (CO/backdraft) check required before close-out. 5. Photograph the finished insulation depth, the final CFM50 reading, and the passed combustion-safety check; file the before/after comparison. Done when: Before/after CFM50 readings from the same blower-door setup + Photos of each sealed leak path and the finished attic/wall insulation depth + Post-tightening combustion-safety (CO/backdraft) check result, passed

Where
1300 block of Duxberry Ave, Linden, Columbus OH 43211 (residential)
Pay
$210 proposed

This packet is not funded yet, so this figure is a proposed price and not money waiting in escrow. If a buyer funds it, approved proof settles that price onchain. If nobody funds it, approved proof earns provable credit toward the work instead of cash. You see which before you claim, never after.

Proof
Before/after CFM50 readings from the same blower-door setup + Photos of each sealed leak path and the finished attic/wall insulation depth + Post-tightening combustion-safety (CO/backdraft) check result, passed

This is exactly what gets it approved. Nothing settles without it.

Level
advanced
Open until
2026-09-01

How this work is done

A documented method, so this packet comes out the same whoever does it. Typically 90–240 minutes. Method of record: Ohio Development Services Agency Home Weatherization Assistance Program (HWAP) — the state pass-through of the DOE Weatherization Assistance Program's cold-climate field protocol: blower-door-directed air sealing toward a CFM50 infiltration target, attic insulation to R-49 / wall cavity to R-13, and mandatory pre/post combustion-safety testing before any tightening closes out.

Bring

Steps

  1. 1. Walk the home with the occupant, note every combustion appliance present, and photograph each nameplate before any work begins.
  2. 2. Set up the calibrated blower door in the main entry and record the baseline CFM50 reading.
  3. 3. Trace and photograph the top infiltration paths with a smoke pencil (rim joist, attic hatch, penetrations, window/door perimeters).
  4. 4. Run the pre-tightening combustion-safety check (ambient CO reading, spillage test at draft hoods) with the blower door off; a failed check stops the job and routes to a licensed HVAC technician before any sealing.
  5. 5. Air-seal the ranked leak paths in order and bring attic insulation to R-49 / accessible wall cavity to R-13 per the HWAP job sheet, maintaining required soffit-to-ridge ventilation.
  6. 6. Re-run the blower-door test to confirm the new CFM50 result.
  7. 7. Run the mandatory post-tightening combustion-safety re-test; a failed re-test stops the job and routes to a licensed HVAC technician for venting correction before further sealing.
  8. 8. Photograph the finished insulation depth and the passed post-tightening combustion-safety check; enter before/after CFM50, materials used, and the combustion-safety result into the proof record; sign.

If it does not match the plan

What counts as done

Proof is measured against these, not judged by taste.

Claim it on the board

Claiming is free. You sign to prove the wallet is yours, and signing costs nothing: no card, no deposit, no fee. An agent can claim this for you with one call to POST /labor/claim, documented at /llms.txt.

Posted pay is not paid pay: settlement follows accepted proof, never the other way around. Vealth does not employ or vet workers, and claiming is not a promise of payment. See how proof and receipts work.