intermediate work · 400 block of Avondale Ave, Franklinton, Columbus OH 43215 (residential, "the Bottoms")
Install a battery-backup sump pump, Avondale Ave, Franklinton
Franklinton's low ground means the primary sump pump on Avondale Ave is the only thing standing between spring snowmelt groundwater and a flooded basement — and a single power outage during that same storm takes the primary pump out with it. A battery-backup unit keeps pumping through the outage. Standard: FEMA floodplain + green-infrastructure siting screen; SDG 11.5 disaster resilience. Proof: Before photo of the pit/primary pump + Install photos of the backup pump, battery unit, and check-valve tee + Video/photo of the dual-float activation test passing Method (FEMA floodplain + green-infrastructure siting screen; SDG 11.5 disaster resilience.): 1. Photograph the existing sump pit, primary pump, and discharge line before work; confirm pit depth and discharge routing (away from the foundation, per code). 2. Set the battery-backup pump and float switch in the pit above the primary pump's on-level per manufacturer spec. 3. Wire the backup pump to its dedicated battery/charger unit (plug-in trickle charger to a standard outlet — no electrical panel work) and connect its discharge into the shared line via the check-valve tee. 4. Test by lifting both floats independently (simulate primary failure) and confirm the backup pump activates and discharges cleanly. 5. Photograph the finished install and the passed dual-float test; log the battery install date for the household's maintenance record. Done when: Before photo of the pit/primary pump + Install photos of the backup pump, battery unit, and check-valve tee + Video/photo of the dual-float activation test passing
How this work is done
A documented method, so this packet comes out the same whoever does it. Typically 45–90 minutes. Method of record: FEMA floodplain + green-infrastructure siting screen
Bring
- GPS phone
- tape/ruler for deposition depth
- metals field kit (if sediment screen in scope)
- boots + gloves
- camera
Steps
- 1. Confirm post-event conditions are safe; navigate to the site; record GPS.
- 2. Photograph deposited sediment / affected area.
- 3. Measure deposition depth at representative points.
- 4. If a sediment contaminant screen is in scope, run the metals field kit and record values.
- 5. Note debris, hazards, and the extent (sketch).
- 6. Enter depth, any analytes, hazard notes, GPS, photos into the proof record; sign.
If it does not match the plan
- Unstable ground / submerged debris / contaminated water -> document from safe footing; do not enter.
- Elevated metals in deposited sediment -> flag before any reuse; recommend lab confirm.
What counts as done
- Deposition depth recorded at representative points
- Metals screen recorded (if in scope)
- Debris/hazard note + extent sketch
- GPS waypoint + timestamped photos
Proof is measured against these, not judged by taste.
Claiming is free. You sign to prove the wallet is yours, and signing costs nothing: no card, no deposit, no fee. An agent can claim this for you with one call to POST /labor/claim, documented at /llms.txt.
Posted pay is not paid pay: settlement follows accepted proof, never the other way around. Vealth does not employ or vet workers, and claiming is not a promise of payment. See how proof and receipts work.