advanced work · 500 block of Gift St, Franklinton, Columbus OH 43215 (residential, "the Bottoms")

Add battery storage to a solar rowhome, Gift St, Franklinton

Gift St's new solar rowhomes export at noon and import at dusk (and Franklinton's flood-prone grid sees more outages than most); a listed battery keeps the clean generation for the evening peak and rides through outages. Standard: Behind-the-meter battery storage — NFPA 855 siting, UL 9540 listed equipment, NEC Article 706 (LBC Energy petal). SDG 7. Proof: Location + clearance photos (NFPA 855) before and after + UL 9540 listing nameplate photo + Commissioning report (charge/discharge + backup transfer) + AHJ inspection pass reference Method (Behind-the-meter battery storage — NFPA 855 siting, UL 9540 listed equipment, NEC Article 706 (LBC Energy petal). SDG 7.): 1. Verify the planned location meets NFPA 855 clearances and the wall/pad carries the weight; photograph the location and main panel before work. 2. Mount the UL 9540 listed battery and gateway per manufacturer torque and clearance specs. 3. A licensed electrician lands conductors, disconnects and overcurrent protection with NEC 706 labeling per the permit plan. 4. Commission per the manufacturer checklist: verify charge/discharge and backup transfer; register monitoring. 5. Pass the AHJ inspection and photograph the installed system, clearances and labels. Done when: Location + clearance photos (NFPA 855) before and after + UL 9540 listing nameplate photo + Commissioning report (charge/discharge + backup transfer) + AHJ inspection pass reference

Where
500 block of Gift St, Franklinton, Columbus OH 43215 (residential, "the Bottoms")
Pay
$200 proposed

This packet is not funded yet, so this figure is a proposed price and not money waiting in escrow. If a buyer funds it, approved proof settles that price onchain. If nobody funds it, approved proof earns provable credit toward the work instead of cash. You see which before you claim, never after.

Proof
Location + clearance photos (NFPA 855) before and after + UL 9540 listing nameplate photo + Commissioning report (charge/discharge + backup transfer) + AHJ inspection pass reference

This is exactly what gets it approved. Nothing settles without it.

Level
advanced
Open until
2026-09-01

How this work is done

A documented method, so this packet comes out the same whoever does it. Typically 360–720 minutes. Method of record: Behind-the-meter battery energy storage installation per NFPA 855 siting + UL 9540 listed equipment + NEC Article 706, under local permit — licensed crew; assess→install→verify

Bring

Steps

  1. 1. ASSESS: verify the planned location meets NFPA 855 clearances (egress, separation, temperature range) and the wall/pad can carry the weight; photograph the location and the main panel before work.
  2. 2. Mount the battery and gateway/inverter per manufacturer torque and clearance specs; anchor seismic where required.
  3. 3. A licensed electrician runs conduit, lands conductors, installs disconnects/overcurrent protection, and applies NEC 706 labeling per the plan set.
  4. 4. Commission: energize per the manufacturer checklist, verify charge/discharge operation and backup transfer (if islanding), and register monitoring.
  5. 5. VERIFY: pass the AHJ inspection; photograph the installed system, clearances, and labels; record the commissioning report and leave the owner the operating guide.

If it does not match the plan

What counts as done

Proof is measured against these, not judged by taste.

Claim it on the board

Claiming is free. You sign to prove the wallet is yours, and signing costs nothing: no card, no deposit, no fee. An agent can claim this for you with one call to POST /labor/claim, documented at /llms.txt.

Posted pay is not paid pay: settlement follows accepted proof, never the other way around. Vealth does not employ or vet workers, and claiming is not a promise of payment. See how proof and receipts work.