intermediate work · Linden STEM Academy, 2626 Cleveland Ave, Columbus OH 43211

Install a restroom exhaust fan, Linden STEM Academy

A K-6 restroom at Linden STEM Academy has no working exhaust, letting humidity and odor build up all day in a heavily-used space. Standard: ASHRAE 62.1 ventilation + EPA IAQ baseline (CO2, PM2.5, VOC, RH); LBC Health+Happiness petal. Proof: Before photo of the restroom ceiling + Install photos of the fan housing and duct run + Airflow test photo/video at the exterior vent cap Method (ASHRAE 62.1 ventilation + EPA IAQ baseline (CO2, PM2.5, VOC, RH); LBC Health+Happiness petal.): 1. Photograph the restroom ceiling/existing fan and confirm the duct route to the exterior. 2. Mount the new fan housing to the ceiling structure per the fan's rough-in spec. 3. Connect the duct to the exterior vent cap and the switch wiring per a licensed electrician's hookup. 4. Test for proper exterior airflow (tissue test at the vent cap) and photograph the finished install. Done when: Before photo of the restroom ceiling + Install photos of the fan housing and duct run + Airflow test photo/video at the exterior vent cap

Where
Linden STEM Academy, 2626 Cleveland Ave, Columbus OH 43211
Pay
$100 proposed

This packet is not funded yet, so this figure is a proposed price and not money waiting in escrow. If a buyer funds it, approved proof settles that price onchain. If nobody funds it, approved proof earns provable credit toward the work instead of cash. You see which before you claim, never after.

Proof
Before photo of the restroom ceiling + Install photos of the fan housing and duct run + Airflow test photo/video at the exterior vent cap

This is exactly what gets it approved. Nothing settles without it.

Level
intermediate
Open until
2026-09-01

How this work is done

A documented method, so this packet comes out the same whoever does it. Typically 45–90 minutes. Method of record: ASHRAE 62.1 + EPA IAQ / moisture baseline

Bring

Steps

  1. 1. Confirm the room/unit and address; coordinate to sample during normal occupancy where relevant.
  2. 2. Photograph the space and any staining/damp/mold.
  3. 3. Place the monitor in the occupied zone; log CO2 over >=1 occupied hour.
  4. 4. Record PM2.5, temperature, and relative humidity.
  5. 5. For moisture/mold scope, take moisture-meter readings at affected vs baseline areas and estimate visible mold area.
  6. 6. Note ventilation type and any obvious deficiencies.
  7. 7. Enter the logs, readings, extent notes, photos into the proof record; sign.

If it does not match the plan

What counts as done

Proof is measured against these, not judged by taste.

Claim it on the board

Claiming is free. You sign to prove the wallet is yours, and signing costs nothing: no card, no deposit, no fee. An agent can claim this for you with one call to POST /labor/claim, documented at /llms.txt.

Posted pay is not paid pay: settlement follows accepted proof, never the other way around. Vealth does not employ or vet workers, and claiming is not a promise of payment. See how proof and receipts work.