Install rooftop solar, Home on Grant St (4600 block), Globeville
Flat and low-slope residential roofs in Globeville sit in full Denver sun producing nothing; the LBC Energy Petal is net-positive energy, and rooftop PV is its primary instrument on this Grant St home. Standard: Rooftop solar PV installation — NEC Article 690 + local AHJ permit, SEIA/NABCEP install best practice (LBC Energy petal). SDG 7. Proof: permit + inspection pass + commissioning photos + GPS Method (Rooftop solar PV installation — NEC Article 690 + local AHJ permit, SEIA/NABCEP install best practice (LBC Energy petal). SDG 7.): 1. Verify the approved permit plan set against the actual roof (structure, shading, layout) and photograph the roof and main panel before work. 2. Install flashed attachments and racking to the structural plan; torque-log every connection and flash every penetration watertight. 3. Mount modules and run wiring per NEC 690; a licensed electrician makes and inspects the terminations. 4. Commission per the inverter checklist at altitude and record initial production. 5. Pass the AHJ final inspection, submit utility permission-to-operate, and photograph the finished array, labels and production reading. Done when: permit + inspection pass + commissioning photos + GPS
How this work is done
A documented method, so this packet comes out the same whoever does it. Typically 480–960 minutes. Method of record: Rooftop solar PV installation to NEC Article 690 + local AHJ permit, per SEIA/NABCEP install best practice — licensed/credentialed crew; assess→install→verify in one job
Bring
- fall protection (anchored harness) + hard hat + gloves (site PPE)
- PV modules, racking/flashing, inverter(s), conduit and NEC 690-rated disconnects per the approved plan set
- torque wrench + multimeter/clamp meter + irradiance or production-check tool
- approved permit plan set + utility interconnection application
Steps
- 1. ASSESS: verify the approved permit plan set matches the roof (structure, rafter condition, shading, array layout); confirm the main panel rating and the planned interconnection method; photograph existing roof + panel before work.
- 2. Install flashed roof attachments and racking to the structural plan (torque to spec, flash every penetration watertight); document torque checks.
- 3. Mount modules, run conduit/wiring, and land the inverter(s) and NEC 690 disconnects and labels exactly per the plan set; a licensed electrician makes and inspects the electrical terminations.
- 4. Commission: energize per the inverter checklist, measure open-circuit/operating values against design, and record initial production.
- 5. VERIFY: pass the AHJ final inspection and submit utility permission-to-operate; photograph the completed array, labels, and production reading; leave the owner the as-built + warranty packet.
If it does not match the plan
- Rotted/soft decking, undersized structure, or panel bus rating below plan -> STOP: route back to engineering/AHJ before any mounting.
- Any wiring or termination outside the licensed electrician's sign-off -> not done; no energization until corrected.
- Work at roof height without anchored fall protection -> STOP work immediately.
What counts as done
- Every roof penetration flashed and photographed; racking torque log complete
- AHJ final inspection passed and utility permission-to-operate submitted/granted
- Initial production reading recorded and within design tolerance, with photo of the meter/app
- As-built plan + labels photographed (NEC 690 rapid-shutdown/disconnect labeling in place)
Proof is measured against these, not judged by taste.