intermediate work · 5200 block of Wilshire Blvd (public right-of-way + typical residential conditions), Los Angeles, CA 90036

Insulate the water heater and attic hatch of a home on the 5200 Wilshire block

Uninsulated water heaters and attic hatches waste heat year-round in this block's older housing stock; wrapping and sealing them is a one-visit efficiency gain on the Energy-Petal ladder. Standard: Living Building Challenge 4.0 — Energy Petal (net-positive energy). Solar, heat pumps, storage, and EV readiness ARE Energy-petal work. SDG 7. Proof: before/after photos + nameplate photo + R-value note + GPS Method (Living Building Challenge 4.0 — Energy Petal (net-positive energy). Solar, heat pumps, storage, and EV readiness ARE Energy-petal work. SDG 7.): 1. Photograph the water heater, its nameplate, and the attic hatch as found; confirm the heater type (wrap electric freely; keep gas-heater wraps clear of the flue, air intake and controls per the wrap instructions). 2. Fit and secure an insulation blanket to the water heater and insulate accessible hot-water pipe runs. 3. Weatherstrip and insulate the attic hatch cover. 4. Photograph the finished work and record material R-values. Done when: before/after photos + nameplate photo + R-value note + GPS

Where
5200 block of Wilshire Blvd (public right-of-way + typical residential conditions), Los Angeles, CA 90036
Pay
$85 proposed

This packet is not funded yet, so this figure is a proposed price and not money waiting in escrow. If a buyer funds it, approved proof settles that price onchain. If nobody funds it, approved proof earns provable credit toward the work instead of cash. You see which before you claim, never after.

Proof
before/after photos + nameplate photo + R-value note + GPS

This is exactly what gets it approved. Nothing settles without it.

Level
intermediate
Open until
2026-09-01

How this work is done

A documented method, so this packet comes out the same whoever does it. Typically 60–150 minutes. Method of record: Living Building Challenge 4.0 Energy Petal — envelope and load reduction verified by measurement before and after, not by installed-product count

Bring

Steps

  1. 1. Photograph each target opening BEFORE, with GPS and timestamp.
  2. 2. Find the leaks: run a smoke pencil around each frame on a windy day or with the exhaust fan running; mark every deflection.
  3. 3. Measure each gap; choose weatherstripping that compresses to the gap, not larger.
  4. 4. Clean the surface — sealant on dust fails within a season.
  5. 5. Seal fixed gaps with backer rod plus caulk; use low-expansion foam only where framing allows.
  6. 6. Fit weatherstripping to operable edges; the door or window must still close and latch without force.
  7. 7. Re-test every sealed opening with the smoke pencil; the deflection must be gone.
  8. 8. Photograph AFTER from the same positions.

If it does not match the plan

What counts as done

Proof is measured against these, not judged by taste.

Claim it on the board

Claiming is free. You sign to prove the wallet is yours, and signing costs nothing: no card, no deposit, no fee. An agent can claim this for you with one call to POST /labor/claim, documented at /llms.txt.

Posted pay is not paid pay: settlement follows accepted proof, never the other way around. Vealth does not employ or vet workers, and claiming is not a promise of payment. See how proof and receipts work.