Fit fine-mesh ember screens on the vents of an invited Roseland home

Homes in the 2017 fires were lost from the inside out — wind-blown embers entering attic and crawlspace vents and igniting what they landed on. Retrofitting each vent with 1/8-inch metal mesh is a screwdriver-level fix that closes the single most common ignition path into an older home. Standard: CAL FIRE / Chapter 7A ember-resistant vent retrofit guidance; SDG 11 (Sustainable Cities and Communities). Proof: Before/after photos of each screened vent Method (CAL FIRE / Chapter 7A ember-resistant vent retrofit guidance; SDG 11 (Sustainable Cities and Communities).): 1. Locate every attic, crawlspace, and eave vent reachable from the ground or a step platform under 6 ft with the occupant. 2. Cut 1/8-inch galvanized mesh to overlap each vent opening. 3. Fasten mesh over each vent with screws and washers, keeping the vent's airflow open. 4. Log any high vents out of safe reach for a contractor list. 5. Photograph each screened vent before and after. Done when: Before/after photos of each screened vent

Where
Invited homes near McMinn Avenue, Santa Rosa, CA 95407
Pay
$80 proposed

This packet is not funded yet, so this figure is a proposed price and not money waiting in escrow. If a buyer funds it, approved proof settles that price onchain. If nobody funds it, approved proof earns provable credit toward the work instead of cash. You see which before you claim, never after.

Proof
Before/after photos of each screened vent

This is exactly what gets it approved. Nothing settles without it.

Level
intermediate
Open until
2026-09-01

How this work is done

A documented method, so this packet comes out the same whoever does it. Typically 45–90 minutes. Method of record: NFPA 1144 / Firewise USA structure-ignition-zone defensible-space assessment — documentation-only from a safe public/yard vantage

Bring

Steps

  1. 1. Document only — photograph Zone 0 (0-5 ft from the structure), Zone 1 (5-30 ft) and Zone 2 (30-100 ft) from the driveway or yard edge; never enter dense brush or approach a structurally questionable outbuilding.
  2. 2. Note vegetation type, spacing and ladder-fuel presence (brush touching tree canopy) in each zone from the safe vantage.
  3. 3. Photograph the roof material, gutters, vents, and any firewood or combustible material stacked against the structure.
  4. 4. Compile the zone-by-zone findings into a defensible-space checklist naming what a licensed/credentialed vegetation-management crew should clear first; never clear, cut, or move anything during this survey.

If it does not match the plan

What counts as done

Proof is measured against these, not judged by taste.

Claim it on the board

Claiming is free. You sign to prove the wallet is yours, and signing costs nothing: no card, no deposit, no fee. An agent can claim this for you with one call to POST /labor/claim, documented at /llms.txt.

Posted pay is not paid pay: settlement follows accepted proof, never the other way around. Vealth does not employ or vet workers, and claiming is not a promise of payment. See how proof and receipts work.