intermediate work · Invited homes, MLK Park neighborhood, Buffalo, NY 14211

Fit interior storm window film on the single-pane windows of an invited Buffalo East Side home

Most East Side houses still carry original single-pane windows that radiate heat out all winter. An interior film kit per window costs a few dollars and returns a measurable share of a heating bill that can rival rent in January. It is the natural second rung after weatherstripping. Standard: DOE storm window and window-film guidance for cold climates; SDG 7. Proof: Before/after photos per filmed window plus a count Method (DOE storm window and window-film guidance for cold climates; SDG 7.): 1. Confirm the occupant invitation and measure each single-pane window to be filmed. 2. Clean the frame and apply the double-sided mounting tape square to the casing. 3. Stretch the film onto the tape and shrink it drum-tight with a hair dryer. 4. Trim edges clean and check for gaps or tears. 5. Photograph each finished window before and after with GPS and date. Done when: Before/after photos per filmed window plus a count

Where
Invited homes, MLK Park neighborhood, Buffalo, NY 14211
Pay
$65 proposed

This packet is not funded yet, so this figure is a proposed price and not money waiting in escrow. If a buyer funds it, approved proof settles that price onchain. If nobody funds it, approved proof earns provable credit toward the work instead of cash. You see which before you claim, never after.

Proof
Before/after photos per filmed window plus a count

This is exactly what gets it approved. Nothing settles without it.

Level
intermediate
Open until
2026-09-01

How this work is done

A documented method, so this packet comes out the same whoever does it. Typically 90–240 minutes. Method of record: Ohio Development Services Agency Home Weatherization Assistance Program (HWAP) — the state pass-through of the DOE Weatherization Assistance Program's cold-climate field protocol: blower-door-directed air sealing toward a CFM50 infiltration target, attic insulation to R-49 / wall cavity to R-13, and mandatory pre/post combustion-safety testing before any tightening closes out.

Bring

Steps

  1. 1. Walk the home with the occupant, note every combustion appliance present, and photograph each nameplate before any work begins.
  2. 2. Set up the calibrated blower door in the main entry and record the baseline CFM50 reading.
  3. 3. Trace and photograph the top infiltration paths with a smoke pencil (rim joist, attic hatch, penetrations, window/door perimeters).
  4. 4. Run the pre-tightening combustion-safety check (ambient CO reading, spillage test at draft hoods) with the blower door off; a failed check stops the job and routes to a licensed HVAC technician before any sealing.
  5. 5. Air-seal the ranked leak paths in order and bring attic insulation to R-49 / accessible wall cavity to R-13 per the HWAP job sheet, maintaining required soffit-to-ridge ventilation.
  6. 6. Re-run the blower-door test to confirm the new CFM50 result.
  7. 7. Run the mandatory post-tightening combustion-safety re-test; a failed re-test stops the job and routes to a licensed HVAC technician for venting correction before further sealing.
  8. 8. Photograph the finished insulation depth and the passed post-tightening combustion-safety check; enter before/after CFM50, materials used, and the combustion-safety result into the proof record; sign.

If it does not match the plan

What counts as done

Proof is measured against these, not judged by taste.

Claim it on the board

Claiming is free. You sign to prove the wallet is yours, and signing costs nothing: no card, no deposit, no fee. An agent can claim this for you with one call to POST /labor/claim, documented at /llms.txt.

Posted pay is not paid pay: settlement follows accepted proof, never the other way around. Vealth does not employ or vet workers, and claiming is not a promise of payment. See how proof and receipts work.