intermediate work · Host-invited home near 11th Ave & Norwalk St, Delano, CA 93215
Install a certified under-sink water filter at an invited Delano home
Delano households that do not trust their tap spend hundreds of dollars a year on bottled water. A certified point-of-use filter rated for the contaminants of local concern, installed once and maintained, cuts that cost and gives the family safe water at the kitchen tap. This is the doing step after a home tap test shows what needs filtering. Standard: NSF/ANSI 53 certified point-of-use filtration; California SAFER program context; SDG 6 Clean Water and Sanitation. Proof: Photos of installed filter, running tap, and leak-free fittings with GPS/date Method (NSF/ANSI 53 certified point-of-use filtration; California SAFER program context; SDG 6 Clean Water and Sanitation.): 1. Confirm the host's tap-test results and bring an NSF/ANSI-certified under-sink filter matched to those results. 2. Shut off the cold-water supply valve under the sink and relieve pressure at the tap. 3. Install the filter unit and cartridge exactly per the manufacturer's instructions, then restore supply. 4. Flush the new cartridge for the time the instructions require and check every fitting for drips. 5. Show the host how and when to change the cartridge, and leave the spare-part model number written down. 6. Photograph the installed unit, the flushed running tap, and record completion with GPS and date. Done when: Photos of installed filter, running tap, and leak-free fittings with GPS/date
How this work is done
A documented method, so this packet comes out the same whoever does it. Typically 30–60 minutes. Method of record: EPA drinking-water sampling (3Ts / LCR first-draw where lead is in scope)
Bring
- GPS-capable phone
- test kit for each named analyte (nitrate/coliform/arsenic/lead as specified)
- clean sample bottle + label
- nitrile gloves
- camera
Steps
- 1. Navigate to the sampling point; confirm GPS is inside the posting radius; record the waypoint.
- 2. Photograph the tap or wellhead with a legible timestamp.
- 3. If first-draw is required, sample after >=6h stagnation; if flushed, run the tap 2-3 minutes first, then sample.
- 4. Fill the bottle without touching the inside; cap immediately.
- 5. Run each test per kit instructions; wait the exact develop/incubation time; read and record every value with units.
- 6. Record coliform as present/absent after the stated incubation window.
- 7. Enter all readings, units, GPS, time, and photos into the proof record; sign it.
If it does not match the plan
- Nitrate > 10 mg/L -> tag 'exceeds EPA MCL'; advise no infant consumption pending certified-lab confirmation.
- Total coliform present -> advise disinfection + retest; recommend lab confirmation.
- Arsenic > 10 ppb or Lead > 15 ppb -> tag exceedance; recommend certified-lab confirmation before any consumption guidance.
What counts as done
- GPS waypoint recorded inside the posting radius
- Timestamped photo of the exact sampling point
- Each required analyte recorded with a numeric value + units (or present/absent)
- Sampling type (first-draw vs flushed) explicitly noted
Proof is measured against these, not judged by taste.
Claiming is free. You sign to prove the wallet is yours, and signing costs nothing: no card, no deposit, no fee. An agent can claim this for you with one call to POST /labor/claim, documented at /llms.txt.
Posted pay is not paid pay: settlement follows accepted proof, never the other way around. Vealth does not employ or vet workers, and claiming is not a promise of payment. See how proof and receipts work.