intermediate work · Invited homes, Tooleville, CA 93221
Install certified filters at invited Tooleville homes still bridging to safe water
Tooleville's two small wells have a long, public record of contamination problems, and even as connection work to Exeter's system progresses, households in the gap still drink from filters or hauled bottles. Certified point-of-use units, installed and tagged at invited homes, hold the line until the pipeline truly lands. Standard: State Water Board SAFER drinking-water program; SDG 6 Clean Water and Sanitation. Proof: Installed certified unit, leak-free and tagged, photographed Method (State Water Board SAFER drinking-water program; SDG 6 Clean Water and Sanitation.): 1. Confirm the invited household's situation; select an NSF/ANSI-certified unit rated for the contaminants named in the posting notes. 2. Shut the cold line; install unit and dedicated tap; check joints for leaks. 3. Flush per manual; tag install and cartridge dates. 4. Teach cartridge changes and the filter's limits. 5. Photograph installed unit, certification mark, and tag, GPS. Done when: Installed certified unit, leak-free and tagged, photographed
How this work is done
A documented method, so this packet comes out the same whoever does it. Typically 30–60 minutes. Method of record: EPA drinking-water sampling (3Ts / LCR first-draw where lead is in scope)
Bring
- GPS-capable phone
- test kit for each named analyte (nitrate/coliform/arsenic/lead as specified)
- clean sample bottle + label
- nitrile gloves
- camera
Steps
- 1. Navigate to the sampling point; confirm GPS is inside the posting radius; record the waypoint.
- 2. Photograph the tap or wellhead with a legible timestamp.
- 3. If first-draw is required, sample after >=6h stagnation; if flushed, run the tap 2-3 minutes first, then sample.
- 4. Fill the bottle without touching the inside; cap immediately.
- 5. Run each test per kit instructions; wait the exact develop/incubation time; read and record every value with units.
- 6. Record coliform as present/absent after the stated incubation window.
- 7. Enter all readings, units, GPS, time, and photos into the proof record; sign it.
If it does not match the plan
- Nitrate > 10 mg/L -> tag 'exceeds EPA MCL'; advise no infant consumption pending certified-lab confirmation.
- Total coliform present -> advise disinfection + retest; recommend lab confirmation.
- Arsenic > 10 ppb or Lead > 15 ppb -> tag exceedance; recommend certified-lab confirmation before any consumption guidance.
What counts as done
- GPS waypoint recorded inside the posting radius
- Timestamped photo of the exact sampling point
- Each required analyte recorded with a numeric value + units (or present/absent)
- Sampling type (first-draw vs flushed) explicitly noted
Proof is measured against these, not judged by taste.