intermediate work · Invited homes near 2nd Street and Napa Avenue, Rodeo, CA 94572

Install a quiet bathroom ventilation fan in an invited Rodeo home that has none

Many small Rodeo homes have no working bath fan, so moisture builds into mold in the same rooms where families already worry about outdoor air. A modern quiet fan on a humidity switch removes moisture at the source. This is the natural next rung after the filter route finds homes with condensation problems. Standard: ASHRAE 62.2 residential ventilation minimums; HUD healthy homes moisture control; SDG 3 (Good Health and Well-Being). Proof: Install-sequence photos plus airflow verification Method (ASHRAE 62.2 residential ventilation minimums; HUD healthy homes moisture control; SDG 3 (Good Health and Well-Being).): 1. Confirm with the occupant that an existing fan opening or accessible ceiling route to an exterior wall or soffit exists. 2. Cut power at the breaker and mount the new quiet fan unit in the ceiling opening. 3. Duct it to the exterior with smooth rigid duct and a backdraft damper — never into the attic space. 4. Wire to the existing switch circuit, restore power, and verify airflow with a tissue test. 5. Photograph the ducted run, the finished fan, and the working tissue test. Done when: Install-sequence photos plus airflow verification

Where
Invited homes near 2nd Street and Napa Avenue, Rodeo, CA 94572
Pay
$360 proposed

This packet is not funded yet, so this figure is a proposed price and not money waiting in escrow. If a buyer funds it, approved proof settles that price onchain. If nobody funds it, approved proof earns provable credit toward the work instead of cash. You see which before you claim, never after.

Proof
Install-sequence photos plus airflow verification

This is exactly what gets it approved. Nothing settles without it.

Level
intermediate
Open until
2026-09-03

How this work is done

A documented method, so this packet comes out the same whoever does it. Typically 45–90 minutes. Method of record: ASHRAE 62.1 + EPA IAQ / moisture baseline

Bring

Steps

  1. 1. Confirm the room/unit and address; coordinate to sample during normal occupancy where relevant.
  2. 2. Photograph the space and any staining/damp/mold.
  3. 3. Place the monitor in the occupied zone; log CO2 over >=1 occupied hour.
  4. 4. Record PM2.5, temperature, and relative humidity.
  5. 5. For moisture/mold scope, take moisture-meter readings at affected vs baseline areas and estimate visible mold area.
  6. 6. Note ventilation type and any obvious deficiencies.
  7. 7. Enter the logs, readings, extent notes, photos into the proof record; sign.

If it does not match the plan

What counts as done

Proof is measured against these, not judged by taste.

Claim it on the board

Claiming is free. You sign to prove the wallet is yours, and signing costs nothing: no card, no deposit, no fee. An agent can claim this for you with one call to POST /labor/claim, documented at /llms.txt.

Posted pay is not paid pay: settlement follows accepted proof, never the other way around. Vealth does not employ or vet workers, and claiming is not a promise of payment. See how proof and receipts work.