Anyone can start here · Invited apartments near Beyer Blvd and Del Sur Blvd, San Diego, CA 92173

Seal the window air conditioner gaps in invited San Ysidro apartments

Window units across San Ysidro's apartment stock leak border-traffic exhaust and valley odors around their side panels day and night. Foam seals and weatherstrip around each unit close the leak paths in under an hour and cut cooling bills at the same time. Standard: DOE Weatherization Assistance Program air-sealing guidance โ€” SDG 7. Proof: Before/after photos per unit Method (DOE Weatherization Assistance Program air-sealing guidance โ€” SDG 7.): 1. Confirm the occupant's invitation and photograph each unit's gaps. 2. Install foam side seals and perimeter weatherstrip so no daylight shows. 3. Add removable caulk rope on the exterior perimeter where the occupant agrees. 4. Photograph each sealed unit inside and out with GPS and date. Done when: Before/after photos per unit

Where
Invited apartments near Beyer Blvd and Del Sur Blvd, San Diego, CA 92173
Pay
$200 proposed

This packet is not funded yet, so this figure is a proposed price and not money waiting in escrow. If a buyer funds it, approved proof settles that price onchain. If nobody funds it, approved proof earns provable credit toward the work instead of cash. You see which before you claim, never after.

Proof
Before/after photos per unit

This is exactly what gets it approved. Nothing settles without it.

Level
entry
Open until
2026-09-03

How this work is done

A documented method, so this packet comes out the same whoever does it. Typically 45โ€“120 minutes. Method of record: US DOE Weatherization Assistance Program DIY-safe air-sealing measures + ENERGY STAR DIY Guide to Sealing and Insulating. Occupant-safe caulk/weatherstrip work only; no combustion, electrical, insulation-removal, or pre-1978 paint disturbance.

Bring

Steps

  1. 1. Photograph each draft location (window trim, door, outlet, penetration) before sealing.
  2. 2. Confirm the home is post-1978 or the surfaces are lead-safe; if pre-1978 with disturbed paint, STOP and flag for a lead-safe pro.
  3. 3. Clean and dry each gap; remove old failed caulk/weatherstrip with the putty knife.
  4. 4. Apply a continuous caulk bead to fixed gaps (window/door trim, penetrations) and tool it smooth.
  5. 5. Install weatherstripping on operable window/door edges so it compresses without binding the sash/door.
  6. 6. Fit door sweeps to exterior doors and foam gaskets behind outlet/switch plates on exterior walls.
  7. 7. Verify each treated opening closes/latches and the seal is continuous; photograph the finished work.
  8. 8. Enter locations sealed, materials used, before/after photos, and any flagged hazard into the proof record; sign.

If it does not match the plan

What counts as done

Proof is measured against these, not judged by taste.

Claim it on the board

Claiming is free. You sign to prove the wallet is yours, and signing costs nothing: no card, no deposit, no fee. An agent can claim this for you with one call to POST /labor/claim, documented at /llms.txt.

Posted pay is not paid pay: settlement follows accepted proof, never the other way around. Vealth does not employ or vet workers, and claiming is not a promise of payment. See how proof and receipts work.