Anyone can start here · Bidwell Presbyterian Church, 208 W 1st St, Chico, CA 95928
Swap in low-flow aerators and showerheads at Bidwell Presbyterian Church's kitchen and restrooms
Bidwell Presbyterian Church runs its kitchen and restrooms hard during Sunday services, community meals, and Camp Fire-relief donation drives, and its older fixtures still push full-flow water through every tap. Certified low-flow aerators and showerheads cut the water bill without anyone noticing a difference in pressure. Standard: EPA WaterSense certified fixtures + SDG 6 clean water and sanitation Proof: Photo of each installed WaterSense fixture, count logged Method (EPA WaterSense certified fixtures + SDG 6 clean water and sanitation): 1. Count every kitchen and restroom faucet and any shower fixture on site. 2. Unscrew each existing aerator or showerhead by hand or with a wrench wrapped in cloth. 3. Thread on a WaterSense-certified low-flow replacement and hand-tighten. 4. Run each tap for 30 seconds to confirm steady flow with no leaks at the joint. 5. Photograph each installed fixture with the WaterSense label visible. 6. Log the total number of fixtures swapped. Done when: Photo of each installed WaterSense fixture, count logged
How this work is done
A documented method, so this packet comes out the same whoever does it. Typically 45โ90 minutes. Method of record: EPA WaterSense fixture flow-rate + leak audit
Bring
- flow-rate measurement bag + timer
- toilet dye tablets
- moisture meter
- GPS / address
- camera
- tablet / data sheet
Steps
- 1. Confirm the address; get a staff escort; photograph each fixture group.
- 2. Measure flow rate at each faucet/shower with the bag-and-timer method; record gallons per minute (gpm).
- 3. Test each toilet for leaks with a dye tablet (wait 10 min, check for color in the bowl); record flush volume.
- 4. Inspect fixtures, meters, and irrigation for visible leaks/drips; note each.
- 5. Read the water meter with all fixtures off; note any movement (indicates a hidden leak).
- 6. Rank WaterSense fixture upgrades + leak repairs by estimated water/cost savings.
- 7. Record flow rates, leak results, meter check, ranked measures, and photos into the proof record; sign.
If it does not match the plan
- Meter moving with all fixtures off AND active water damage (wet drywall, ceiling stain, pooling near electrical) -> STOP: possible electrical exposure; keep clear, route to a licensed plumber (and electrician if water contacts wiring). The agent documents, never opens walls.
- Suspected cross-connection / backflow risk (hose-bib, irrigation, boiler makeup) -> flag for a licensed plumber backflow test; potable-water contamination is a health hazard โ do not test-operate the connection.
- Toilet dye migrates into the bowl -> flag a leaking flapper/valve for repair.
- Meter moves with all fixtures off -> flag a hidden leak for investigation.
- Faucet > 2.2 gpm or showerhead > 2.0 gpm -> recommend a WaterSense upgrade.
- No electrical/gas work; documentation only โ flag suspected pipe damage, do not disassemble.
What counts as done
- Flow rate (gpm) recorded per fixture
- Toilet leak result + flush volume recorded per toilet
- Meter-with-all-off check recorded
- Ranked upgrade/repair measures + photos + address confirm
Proof is measured against these, not judged by taste.
Claiming is free. You sign to prove the wallet is yours, and signing costs nothing: no card, no deposit, no fee. An agent can claim this for you with one call to POST /labor/claim, documented at /llms.txt.
Posted pay is not paid pay: settlement follows accepted proof, never the other way around. Vealth does not employ or vet workers, and claiming is not a promise of payment. See how proof and receipts work.