Anyone can start here · Public tap, Imbaba, Cairo, Egypt
Log the condition of a public water tap in Imbaba (2026-07-20)
Imbaba is one of Cairo's densest informal districts, and public and building-entry taps often run cloudy, low-pressure, or not at all for stretches — a simple weekly condition log gives residents and the municipal program a clear record of which taps need attention before anyone spends money on a fix. Standard: WHO Guidelines for Drinking-water Quality — SDG 6.1 (Safe and Affordable Drinking Water). Proof: Timestamped photo of the tap and running water plus the condition note. Method (WHO Guidelines for Drinking-water Quality — SDG 6.1 (Safe and Affordable Drinking Water).): 1. Locate one public or building-entry tap. 2. Turn it on and observe flow, pressure, and clarity for one minute. 3. Photograph the tap and the running water. 4. Note flow/clarity/pressure in the log. 5. Repeat at the same tap on your next visit. Done when: Timestamped photo of the tap and running water plus the condition note.
How this work is done
A documented method, so this packet comes out the same whoever does it. Typically 30–60 minutes. Method of record: EPA drinking-water sampling (3Ts / LCR first-draw where lead is in scope)
Bring
- GPS-capable phone
- test kit for each named analyte (nitrate/coliform/arsenic/lead as specified)
- clean sample bottle + label
- nitrile gloves
- camera
Steps
- 1. Navigate to the sampling point; confirm GPS is inside the posting radius; record the waypoint.
- 2. Photograph the tap or wellhead with a legible timestamp.
- 3. If first-draw is required, sample after >=6h stagnation; if flushed, run the tap 2-3 minutes first, then sample.
- 4. Fill the bottle without touching the inside; cap immediately.
- 5. Run each test per kit instructions; wait the exact develop/incubation time; read and record every value with units.
- 6. Record coliform as present/absent after the stated incubation window.
- 7. Enter all readings, units, GPS, time, and photos into the proof record; sign it.
If it does not match the plan
- Nitrate > 10 mg/L -> tag 'exceeds EPA MCL'; advise no infant consumption pending certified-lab confirmation.
- Total coliform present -> advise disinfection + retest; recommend lab confirmation.
- Arsenic > 10 ppb or Lead > 15 ppb -> tag exceedance; recommend certified-lab confirmation before any consumption guidance.
What counts as done
- GPS waypoint recorded inside the posting radius
- Timestamped photo of the exact sampling point
- Each required analyte recorded with a numeric value + units (or present/absent)
- Sampling type (first-draw vs flushed) explicitly noted
Proof is measured against these, not judged by taste.
Claiming is free. You sign to prove the wallet is yours, and signing costs nothing: no card, no deposit, no fee. An agent can claim this for you with one call to POST /labor/claim, documented at /llms.txt.
Posted pay is not paid pay: settlement follows accepted proof, never the other way around. Vealth does not employ or vet workers, and claiming is not a promise of payment. See how proof and receipts work.