Anyone can start here · Civic Center Dr community building, North Las Vegas, NV

Install low-flow fixtures in the restrooms at the Civic Center Drive community building

The public restrooms at the community building on Civic Center Drive in North Las Vegas still run older showerheads and faucet aerators in a desert valley where every gallon of treated water carries a real cost. Low-flow fixtures cut that draw without changing how the fixtures feel to use. Standard: LBC Water Petal, Net Positive Water Imperative Proof: Photo of each new fixture plus a written count of fixtures replaced. Method (LBC Water Petal, Net Positive Water Imperative): 1. Shut off the water supply at each fixture to be upgraded. 2. Remove the old showerhead, faucet aerator, or flush valve. 3. Thread on the new low-flow fixture and check the seal with a wrench snug, not overtightened. 4. Restore water and run each fixture to check for leaks and even flow. 5. Log the fixtures replaced and photograph the finished install. Done when: Photo of each new fixture plus a written count of fixtures replaced.

Where
Civic Center Dr community building, North Las Vegas, NV
Pay
$220 proposed

This packet is not funded yet, so this figure is a proposed price and not money waiting in escrow. If a buyer funds it, approved proof settles that price onchain. If nobody funds it, approved proof earns provable credit toward the work instead of cash. You see which before you claim, never after.

Proof
Photo of each new fixture plus a written count of fixtures replaced.

This is exactly what gets it approved. Nothing settles without it.

Level
entry
Open until
2026-09-03

How this work is done

A documented method, so this packet comes out the same whoever does it. Typically 45โ€“90 minutes. Method of record: EPA WaterSense fixture flow-rate + leak audit

Bring

Steps

  1. 1. Confirm the address; get a staff escort; photograph each fixture group.
  2. 2. Measure flow rate at each faucet/shower with the bag-and-timer method; record gallons per minute (gpm).
  3. 3. Test each toilet for leaks with a dye tablet (wait 10 min, check for color in the bowl); record flush volume.
  4. 4. Inspect fixtures, meters, and irrigation for visible leaks/drips; note each.
  5. 5. Read the water meter with all fixtures off; note any movement (indicates a hidden leak).
  6. 6. Rank WaterSense fixture upgrades + leak repairs by estimated water/cost savings.
  7. 7. Record flow rates, leak results, meter check, ranked measures, and photos into the proof record; sign.

If it does not match the plan

What counts as done

Proof is measured against these, not judged by taste.

Claim it on the board

Claiming is free. You sign to prove the wallet is yours, and signing costs nothing: no card, no deposit, no fee. An agent can claim this for you with one call to POST /labor/claim, documented at /llms.txt.

Posted pay is not paid pay: settlement follows accepted proof, never the other way around. Vealth does not employ or vet workers, and claiming is not a promise of payment. See how proof and receipts work.