intermediate work · community site, Denmark, SC
Install a filtered water refill station at a Denmark community site
Denmark residents have raised long-standing concerns about their tap water, and a filtered public refill station at a community site gives people a trusted place to fill a bottle. Standard: EPA Safe Drinking Water Act, household and public tap water monitoring Proof: Before/after photos of the install site plus a leak check note. Method (EPA Safe Drinking Water Act, household and public tap water monitoring): 1. Confirm the water line and drain access at the public site chosen in community site, Denmark, SC. 2. Mount the filtered refill station per the manufacturer instructions. 3. Connect the water supply line and the filter cartridge. 4. Run water through the new filter to flush it and check for leaks. 5. Photograph the finished station and post simple use instructions. Done when: Before/after photos of the install site plus a leak check note.
How this work is done
A documented method, so this packet comes out the same whoever does it. Typically 30–60 minutes. Method of record: EPA drinking-water sampling (3Ts / LCR first-draw where lead is in scope)
Bring
- GPS-capable phone
- test kit for each named analyte (nitrate/coliform/arsenic/lead as specified)
- clean sample bottle + label
- nitrile gloves
- camera
Steps
- 1. Navigate to the sampling point; confirm GPS is inside the posting radius; record the waypoint.
- 2. Photograph the tap or wellhead with a legible timestamp.
- 3. If first-draw is required, sample after >=6h stagnation; if flushed, run the tap 2-3 minutes first, then sample.
- 4. Fill the bottle without touching the inside; cap immediately.
- 5. Run each test per kit instructions; wait the exact develop/incubation time; read and record every value with units.
- 6. Record coliform as present/absent after the stated incubation window.
- 7. Enter all readings, units, GPS, time, and photos into the proof record; sign it.
If it does not match the plan
- Nitrate > 10 mg/L -> tag 'exceeds EPA MCL'; advise no infant consumption pending certified-lab confirmation.
- Total coliform present -> advise disinfection + retest; recommend lab confirmation.
- Arsenic > 10 ppb or Lead > 15 ppb -> tag exceedance; recommend certified-lab confirmation before any consumption guidance.
What counts as done
- GPS waypoint recorded inside the posting radius
- Timestamped photo of the exact sampling point
- Each required analyte recorded with a numeric value + units (or present/absent)
- Sampling type (first-draw vs flushed) explicitly noted
Proof is measured against these, not judged by taste.
Claiming is free. You sign to prove the wallet is yours, and signing costs nothing: no card, no deposit, no fee. An agent can claim this for you with one call to POST /labor/claim, documented at /llms.txt.
Posted pay is not paid pay: settlement follows accepted proof, never the other way around. Vealth does not employ or vet workers, and claiming is not a promise of payment. See how proof and receipts work.