intermediate work · Kamehameha Ave, Hilo, HI
Install a rooftop rainwater catchment cistern at a Hilo home
With gutters clear, this Hilo home can now put its heavy rainfall to use instead of losing it all to the storm drain. A rooftop catchment cistern stores that water for garden and household use, the intermediate rung in Hilo's rain-catchment chain. Standard: SDG 6, Clean Water and Sanitation, rooftop rainwater catchment Proof: Photo shows installed cistern catching flow with a working overflow Method (SDG 6, Clean Water and Sanitation, rooftop rainwater catchment): 1. Confirm the roof catchment area and downspout routing 2. Set the cistern on a level, stable base 3. Connect the downspout to the cistern inlet with a first-flush diverter 4. Fit an overflow outlet directed away from the foundation 5. Test the system by running water through the downspout into the cistern Done when: Photo shows installed cistern catching flow with a working overflow
How this work is done
A documented method, so this packet comes out the same whoever does it. Typically 30–60 minutes. Method of record: EPA drinking-water sampling (3Ts / LCR first-draw where lead is in scope)
Bring
- GPS-capable phone
- test kit for each named analyte (nitrate/coliform/arsenic/lead as specified)
- clean sample bottle + label
- nitrile gloves
- camera
Steps
- 1. Navigate to the sampling point; confirm GPS is inside the posting radius; record the waypoint.
- 2. Photograph the tap or wellhead with a legible timestamp.
- 3. If first-draw is required, sample after >=6h stagnation; if flushed, run the tap 2-3 minutes first, then sample.
- 4. Fill the bottle without touching the inside; cap immediately.
- 5. Run each test per kit instructions; wait the exact develop/incubation time; read and record every value with units.
- 6. Record coliform as present/absent after the stated incubation window.
- 7. Enter all readings, units, GPS, time, and photos into the proof record; sign it.
If it does not match the plan
- Nitrate > 10 mg/L -> tag 'exceeds EPA MCL'; advise no infant consumption pending certified-lab confirmation.
- Total coliform present -> advise disinfection + retest; recommend lab confirmation.
- Arsenic > 10 ppb or Lead > 15 ppb -> tag exceedance; recommend certified-lab confirmation before any consumption guidance.
What counts as done
- GPS waypoint recorded inside the posting radius
- Timestamped photo of the exact sampling point
- Each required analyte recorded with a numeric value + units (or present/absent)
- Sampling type (first-draw vs flushed) explicitly noted
Proof is measured against these, not judged by taste.
Claiming is free. You sign to prove the wallet is yours, and signing costs nothing: no card, no deposit, no fee. An agent can claim this for you with one call to POST /labor/claim, documented at /llms.txt.
Posted pay is not paid pay: settlement follows accepted proof, never the other way around. Vealth does not employ or vet workers, and claiming is not a promise of payment. See how proof and receipts work.