Anyone can start here · 112 Katahdin Ave, Millinocket, ME 04462

Weatherstrip a Katahdin Avenue duplex in Millinocket (2026-07-20)

A duplex on Katahdin Avenue, built for Great Northern Paper mill workers, has original 1930s window and door seals that have failed, and winter heating costs are pushing the household budget hard. The resident needs a full weatherstripping pass before the cold sets in. Standard: Efficiency Maine / NEEP cold-climate weatherization guidance Proof: Before and after photos of every sealed opening plus a GPS-tagged confirmation of the address. Method (Efficiency Maine / NEEP cold-climate weatherization guidance): 1. Walk the home with the resident and mark every door and window with a visible draft. 2. Measure and cut new weatherstripping or a door sweep for each marked opening. 3. Strip off the old, failed material and clean the frame surface. 4. Install the new seal and fasten it along the full length of the opening. 5. Recheck each opening for daylight or draft and log the sealed count. Done when: Before and after photos of every sealed opening plus a GPS-tagged confirmation of the address.

Where
112 Katahdin Ave, Millinocket, ME 04462
Pay
$180 proposed

This packet is not funded yet, so this figure is a proposed price and not money waiting in escrow. If a buyer funds it, approved proof settles that price onchain. If nobody funds it, approved proof earns provable credit toward the work instead of cash. You see which before you claim, never after.

Proof
Before and after photos of every sealed opening plus a GPS-tagged confirmation of the address.

This is exactly what gets it approved. Nothing settles without it.

Level
entry
Open until
2026-08-19

How this work is done

A documented method, so this packet comes out the same whoever does it. Typically 90–240 minutes. Method of record: Ohio Development Services Agency Home Weatherization Assistance Program (HWAP) — the state pass-through of the DOE Weatherization Assistance Program's cold-climate field protocol: blower-door-directed air sealing toward a CFM50 infiltration target, attic insulation to R-49 / wall cavity to R-13, and mandatory pre/post combustion-safety testing before any tightening closes out.

Bring

Steps

  1. 1. Walk the home with the occupant, note every combustion appliance present, and photograph each nameplate before any work begins.
  2. 2. Set up the calibrated blower door in the main entry and record the baseline CFM50 reading.
  3. 3. Trace and photograph the top infiltration paths with a smoke pencil (rim joist, attic hatch, penetrations, window/door perimeters).
  4. 4. Run the pre-tightening combustion-safety check (ambient CO reading, spillage test at draft hoods) with the blower door off; a failed check stops the job and routes to a licensed HVAC technician before any sealing.
  5. 5. Air-seal the ranked leak paths in order and bring attic insulation to R-49 / accessible wall cavity to R-13 per the HWAP job sheet, maintaining required soffit-to-ridge ventilation.
  6. 6. Re-run the blower-door test to confirm the new CFM50 result.
  7. 7. Run the mandatory post-tightening combustion-safety re-test; a failed re-test stops the job and routes to a licensed HVAC technician for venting correction before further sealing.
  8. 8. Photograph the finished insulation depth and the passed post-tightening combustion-safety check; enter before/after CFM50, materials used, and the combustion-safety result into the proof record; sign.

If it does not match the plan

What counts as done

Proof is measured against these, not judged by taste.

Claim it on the board

Claiming is free. You sign to prove the wallet is yours, and signing costs nothing: no card, no deposit, no fee. An agent can claim this for you with one call to POST /labor/claim, documented at /llms.txt.

Posted pay is not paid pay: settlement follows accepted proof, never the other way around. Vealth does not employ or vet workers, and claiming is not a promise of payment. See how proof and receipts work.