Succ Drinking Water Safety
Install a point-of-use water filter.
The owner's licensed plumber shuts off the water supply, cuts the tubing with a tubing cutter and wrenches a certified point-of-use filter onto the tap, while the crew tags the fixture out of service. Read all of it
Not funded yet. Settles as earned credit, $85 proposed.
Proof it takes, the deadline, the level
- Proofbefore/after test readings + NSF/ANSI label photo + install date/next-service label + GPS waypoint: Real, Proven, One-of-one
- Open until2026-10-23
- Leveladvanced
All of it: the words, the place, the proof
Install an NSF/ANSI-certified point-of-use filter on the tap or spigot this source feeds at Arleta community center, Los Angeles CA. The potability test flagged a contaminant, so size the filter to it and confirm the fix with a retest. A potability test flagged a contaminant in the water from this tap, and the tap has no point-of-use filter. The tap delivers water that a potability test flagged as contaminated, and nothing at the tap treats it. For the payer: - Price: $85 per job, counted in filters installed. - Likely payer: The building's owner or manager, paying directly. - License: CSLB C-36 Plumbing for the pipe connection; C-55 Water Conditioning for the filter.
Fund it for $85. The receipt lands onchain once the proof is approved.
Safety, read before you claim
Start after the crew's safety orientation. Stop and route this job to the owner's licensed plumber, the water utility and the local health department: a flagged drinking water result is theirs to treat and re-sample, no crew plumbs, cuts, joins or re-tests a drinking supply on this program, and no one solders or sweats copper. Whoever installs never says the water is fit to drink; only a State-accredited laboratory result, read by the owner and the health department, says anything about the water; wear slip-resistant closed-toe shoes and nitrile gloves.
The full safety list for this job:
- A systemic municipal or utility-source contamination, or a whole-building lead result at or above the EPA action level, is not DIY-scoped.
- Point-of-entry treatment and service-line work route to the water utility, the local health department, or a licensed plumber.
- STOP and route to the water utility, the local health department, or a licensed plumber if the contamination is systemic.
- A point-of-use filter does not remove every contaminant: lead, nitrate, PFAS, bacteria and disinfection byproducts each need a different treatment, and a wrong cartridge or one past its change date can grow bacteria and give false comfort. A first-draw sample and a flushed sample give different numbers; the owner's sampling plan says which counts. Keep the tap tagged out of service until the owner's plumber returns it. No one adds chlorine or any chemical to a drinking supply on this program.
- Orientation to the plan before touching a drinking supply: who to call, what to stop for (Title 8 section 3203).
- Labels and Safety Data Sheets for thread sealant, cleaners and any sanitizer used on the device (Title 8 section 5194).
- Eye protection under a sink; water and debris fall in the face (Title 8 section 3382).
- Older brass and solder can hold lead: no cutting, sanding or heating of old joints on this job (Title 8 section 1532.1).
- Gear, Title 8 sections 3385 and 3384: slip-resistant closed-toe shoes for wet floors and dropped fixtures; nitrile gloves for descaler, cleaners and sealant.
- Held until a licensed crew does it: it takes a CSLB C-36 license and the owner's or agency's written permit for this exact work, both recorded before any work starts.
How this work is done
How this work is done
A documented method, so this packet comes out the same whoever does it.
Bring
- none for a crew; the owner's plumber supplies the device, tools and labels
Steps
- Obtain the owner's or manager's written consent for this work at this address before you start (a signed form, an email or a text that names the address and the work). Write who gave it and the date at the top of your proof. With no consent, stop.
- Confirm with the facility manager which fixture is being treated, that it is on the building's fixture inventory, and what the flagged result actually was: contaminant, concentration, sample date, and whether it was a first-draw or flushed sample. An institutional building's sampling plan is a regulated document; read it rather than assuming.
- The owner's plumber or the health department chooses the treatment; the crew never selects a device.
- Confirm before touching the plumbing whether the jurisdiction or the building requires a licensed plumber, a permit, or a backflow review for this installation. Where it does, the install is theirs; document the scope and hand it over.
- Notify anyone who uses the fixture that it is out of service and tag the tap. The owner's plumber shuts off the supply, installs the device per the manufacturer's instructions and restores service; plumber only.
- The owner's plumber flushes and primes the device through the manufacturer's full start-up procedure and signs. The crew never returns a drinking tap to use; keep it tagged out of service until the plumber finishes.
- A State-accredited laboratory takes any retest, under the owner's sampling plan. The crew records only that the device was installed and the tap tagged.
- Label the unit with the install date and the next filter-change date, add it to the building's maintenance schedule so the change actually happens, and give the facility manager a plain-language card covering what it does, what it does not do, and who services it.
- Enter photos, GPS/address, the device model and certification, the before and after results with their sample dates, and the schedule entry; sign.
What counts as done
- Photo of the flagged test result being remedied
- NSF/ANSI certification label photo of the installed device
- Post-install retest reading confirming the contaminant is below the safety threshold
- GPS waypoint of the installed device
- The owner's written direction.
- The plumber's name and the license number as given by the owner (it can be checked on cslb.ca.gov).
- Photo of the device model label.
- The filter change-by date.
- The laboratory result stays with the owner; this proof carries no retest reading and no 'below the safety threshold' claim.
- Consent: the owner's or manager's written consent, naming the address and the work, dated before the first photo.
- Sign-off: the owner or manager signs off the finished work in writing. Write who signed and the date, or the date you asked.
- Photos: take the before photo and the after photo from the same point (stand where the first one was taken and match its frame), each with its GPS point and its date and time.
Proof is measured against these, not judged by taste.
What is promised, and what is not
Three separate acts, never one: a vote is a free signed preference that moves no money; a pledge is free signed backing intent, balance-checked, that moves no money and never marks the packet funded; funding is a real payment that backs the wage, plus one Vealth service fee of 10% shown apart; the worker is paid the whole wage. Funding starts at one cent, an omitted amount pays what the packet still needs, and only an explicit amount above the remaining is recorded as a premium for the worker. Money settles only on accepted proof. An agent can fund it in one x402 call: POST /nurture/fund {"workId":"WORK_1784869150777_w1nvrax","funderWallet":"0xYOU"}.
Open, but not claimable yet. restricted: permit-required, regulated. Regulated or permit-required work cannot be claimed on this rail yet. It stays readable; voting and pledging are free, and funding is separate from claiming.
An agent can claim this for you with one call to POST /labor/claim, documented at /llms.txt.
Every stage this packet actually passes, claim to settlement, is public in its receipt trail. A stage that has not happened is not claimed.
Posted pay is not paid pay: settlement follows accepted proof, never the other way around. Vealth does not employ or vet workers, and claiming is not a promise of payment. See how proof and receipts work.
Other acts: vote, pledge, fund
Packet WORK_1784869150777_w1nvrax