Anyone can start here · Chamizal National Memorial, El Paso, TX

Install a first-flush diverter on an existing rain cistern: Chamizal National Memorial, TX

Desert rain is rare and precious; the first roof flush carries dust into the cistern and spoils the stored water. A simple diverter retrofit makes every stored gallon usable. Site: Chamizal National Memorial, El Paso, TX. Standard: ARCSA rainwater harvesting guidance, first-flush diverter retrofit on an existing downspout and cistern; hand tools; SDG 6.4 Proof: before/after photos of the downspout + diverter, first-flush volume noted, GPS Method (First-flush diverter retrofit per ARCSA guidance: measure the downspout, cut in the diverter tee at chest height, size the flush chamber to the roof area, seal, photo verify. Ground level only., ~60-150 min): 1. Photo the downspout and cistern as found. 2. Measure and mark the tee position at chest height. 3. Fit the diverter per kit instructions and seal. 4. After photo + note the flush chamber sizing. Equipment: diverter kit sized to the downspout, hand saw + measuring tape, sealant per kit, camera + GPS phone Done when: Diverter tee installed at chest height and sealed, no leaks on test pour; Flush chamber sized to the roof area (sizing noted in proof); Before/after photos + GPS

Where
Chamizal National Memorial, El Paso, TX
Pay
$80 proposed

This packet is not funded yet, so this figure is a proposed price and not money waiting in escrow. If a buyer funds it, approved proof settles that price onchain. If nobody funds it, approved proof earns provable credit toward the work instead of cash. You see which before you claim, never after.

Proof
before/after photos of the downspout + diverter, first-flush volume noted, GPS

This is exactly what gets it approved. Nothing settles without it.

Level
entry
Open until
2026-08-23

How this work is done

A documented method, so this packet comes out the same whoever does it. Typically 60–150 minutes. Method of record: First-flush diverter retrofit per ARCSA guidance: measure the downspout, cut in the diverter tee at chest height, size the flush chamber to the roof area, seal, photo verify. Ground level only.

Bring

Steps

  1. 1. Photo the downspout and cistern as found.
  2. 2. Measure and mark the tee position at chest height.
  3. 3. Fit the diverter per kit instructions and seal.
  4. 4. After photo + note the flush chamber sizing.

If it does not match the plan

What counts as done

Proof is measured against these, not judged by taste.

Claim it on the board

Claiming is free. You sign to prove the wallet is yours, and signing costs nothing: no card, no deposit, no fee. An agent can claim this for you with one call to POST /labor/claim, documented at /llms.txt.

Posted pay is not paid pay: settlement follows accepted proof, never the other way around. Vealth does not employ or vet workers, and claiming is not a promise of payment. See how proof and receipts work.