intermediate work · Holland Avenue / US Highway 90 corridor, downtown Alpine, TX 79830 (public right of way)
Shield a corridor light fixture to a dark-sky-compliant full-cutoff design, fixture 2, Holland Avenue / US Highway 90 corridor, downtown Alpine, TX 79830 (public right of way)
A ground-accessible outdoor light fixture along this downtown Alpine corridor throws unshielded glare upward and outward, wasting electricity and washing out the Trans-Pecos night sky that the region's dark-sky tourism and McDonald Observatory research depend on. Standard: ASHRAE Level 1 energy audit plus Living Building Challenge Energy petal screening, applied here against Alpine's high-desert cooling and heating load and its dark-sky night-lighting footprint. Proof: before/after photos (day and night) + fixture spec sheet + power-off confirm + GPS Method (ASHRAE Level 1 energy audit plus Living Building Challenge Energy petal screening, applied here against Alpine's high-desert cooling and heating load and its dark-sky night-lighting footprint.): 1. 1. Confirm the fixture with city staff: ground-accessible, building- or park-pole mounted only, never an overhead utility-owned cobra-head streetlight, and photograph the bare, unshielded fixture before starting. 2. 2. Power off the fixture at its switch or breaker before touching any wiring or lamp. 3. 3. Install a full-cutoff, dark-sky-compliant shield or fixture housing so light points down and not outward or upward, working from a properly rated ladder with a spotter. 4. 4. Restore power and photograph the shielded fixture lit at night alongside the daytime after photo, confirming no upward glare. Done when: before/after photos (day and night) + fixture spec sheet + power-off confirm + GPS
How this work is done
A documented method, so this packet comes out the same whoever does it. Typically 60–120 minutes. Method of record: ASHRAE Level 1 energy audit
Bring
- tablet/clipboard
- tape measure
- light meter (lighting scope)
- clamp thermometer (refrigeration scope)
- 12-month utility bills
- camera
- ladder + spotter (high fixtures)
Steps
- 1. Confirm the address; arrange a staff escort for mechanical/back-of-house.
- 2. Photograph HVAC, lighting, envelope, and any in-scope systems.
- 3. Inventory systems: HVAC type + age; lighting fixture count/type/wattage; refrigeration units; envelope condition.
- 4. Summarize 12 months of utility use (kWh / therms) from the bills.
- 5. Take the in-scope measurements (light levels, unit temperatures, seal condition).
- 6. Rank no-cost/low-cost measures, then capital measures, with rough savings logic.
- 7. Enter inventory, measurements, utility summary, photos, and the ranked measure list; sign.
If it does not match the plan
- Knob-and-tube, ungrounded or overheated wiring, scorched outlets, or a hot electrical panel -> STOP: do not operate the circuit; route to a licensed electrician and restrict use (NEC / fire hazard).
- Gas odor, or a combustion appliance with absent/blocked venting (backdrafting / CO risk) -> STOP: evacuate, ventilate, call the gas utility. The agent escalates, never relights or adjusts gas.
- Any live-electrical/gas hazard -> document, do not touch, flag for a licensed pro.
- Refrigeration unit out of food-safe range -> flag as both energy and food-safety risk.
- Suspected asbestos/lead in materials -> flag and stop.
What counts as done
- System inventory complete for the in-scope equipment
- 12-month utility use summary recorded
- In-scope measurements recorded with units
- Ranked no-cost/low-cost + capital measure list produced
Proof is measured against these, not judged by taste.
Claiming is free. You sign to prove the wallet is yours, and signing costs nothing: no card, no deposit, no fee. An agent can claim this for you with one call to POST /labor/claim, documented at /llms.txt.
Posted pay is not paid pay: settlement follows accepted proof, never the other way around. Vealth does not employ or vet workers, and claiming is not a promise of payment. See how proof and receipts work.