advanced work · a community building in Lewiston, ME
Repair the building envelope at a community building in Lewiston, ME (2026-07-31)
The masonry, trim, or envelope at a community building in Lewiston, ME has weathered and cracked, letting water and air through. This repoints and seals it to protect the structure. Standard: LBC (Living Building Challenge) Materials petal envelope-maintenance practice Proof: Before and after photos of the repointed section plus a GPS tag and cure-date log. Method (LBC (Living Building Challenge) Materials petal envelope-maintenance practice): 1. Inspect the ground-level mortar joints and mark every section with crumbling or missing mortar. 2. Rake out the failed mortar to a consistent depth using hand tools. 3. Mix a mortar batch matched to the original in strength and color. 4. Pack the new mortar into the joints and tool it to match the surrounding profile. 5. Cure and photograph the repointed section once set. Done when: before photo; after photo; GPS location tag; written cure-date log
How this work is done
A documented method, so this packet comes out the same whoever does it. Typically 90–180 minutes. Method of record: Ground-level mortar-joint repointing on a rowhouse brick facade or water table, per NPS Preservation Brief 2 (Repointing Mortar Joints in Historic Masonry Buildings)
Bring
- masonry chisel + hammer or grinder with dust-control shroud (joint raking)
- mortar matched to the original mix/color + pointing trowel + tuck pointer
- water brush + mixing bucket
- camera + tape measure
Steps
- 1. ASSESS: photograph the failing joints and measure the extent; confirm the work is reachable from the ground or a short step stool (no scaffold, no work above 6 ft) and that the mortar type is compatible with the original masonry (avoid hard portland-cement mortar on soft historic brick).
- 2. Rake out the failed mortar to a consistent depth (roughly 2-2.5x the joint width) without damaging the brick edges; brush and dampen the joint.
- 3. Pack and tool the matched mortar into the joint in lifts, matching the original joint profile and color.
- 4. Cure per spec (mist and protect from rapid drying) and photograph the finished joints from the same before vantage.
If it does not match the plan
- Any work that would require scaffold or reach above 6 ft -> STOP; name the licensed masonry-crew job instead.
- Structural cracking (not just failed mortar) or a bulging/leaning wythe -> STOP, route to a structural assessor before repointing.
What counts as done
- Repointed joints match the original profile, width and (as closely as sourced) color
- No hard/incompatible mortar used on historic soft brick
- Before/after photos from a matching vantage
- Work stayed at or below reachable ground-level height — no scaffold used
Proof is measured against these, not judged by taste.