Anyone can start here · Public tap, Imbaba, Cairo, Egypt
Log the condition of a public water tap in Imbaba (2026-08-03)
Log the condition of a public water tap in Imbaba (2026-08-03). Fund it for $140. Proof lands on-chain when it's done.
Imbaba is one of Cairo's densest informal districts, and public and building-entry taps often run cloudy, low-pressure, or not at all for stretches. A simple weekly condition log gives residents and the municipal program a clear record of which taps need attention before anyone spends money on a fix. Standard: WHO Guidelines for Drinking-water Quality: SDG 6.1 (Safe and Affordable Drinking Water). Proof: Timestamped photo of the tap and running water plus the condition note. Method (WHO Guidelines for Drinking-water Quality: SDG 6.1 (Safe and Affordable Drinking Water).): 1. Locate one public or building-entry tap. 2. Turn it on and observe flow, pressure, and clarity for one minute. 3. Photograph the tap and the running water. 4. Note flow/clarity/pressure in the log. 5. Repeat at the same tap on your next visit. Done when: Photo of the tap with GPS pin and timestamp; Photo or short video of the water running; Written flow/clarity/pressure note
How this work is done
A documented method, so this packet comes out the same whoever does it. Typically 30–60 minutes. Method of record: EPA drinking-water sampling (3Ts / LCR first-draw where lead is in scope)
Bring
- GPS-capable phone
- test kit for each named analyte (nitrate/coliform/arsenic/lead as specified)
- clean sample bottle + label
- nitrile gloves
- camera
Steps
- 1. Navigate to the sampling point; confirm GPS is inside the posting radius; record the waypoint.
- 2. Photograph the tap or wellhead with a legible timestamp.
- 3. If first-draw is required, sample after >=6h stagnation; if flushed, run the tap 2-3 minutes first, then sample.
- 4. Fill the bottle without touching the inside; cap immediately.
- 5. Run each test per kit instructions; wait the exact develop/incubation time; read and record every value with units.
- 6. Record coliform as present/absent after the stated incubation window.
- 7. Enter all readings, units, GPS, time, and photos into the proof record; sign it.
If it does not match the plan
- Nitrate > 10 mg/L -> tag 'exceeds EPA MCL'; advise no infant consumption pending certified-lab confirmation.
- Total coliform present -> advise disinfection + retest; recommend lab confirmation.
- Arsenic > 10 ppb or Lead > 15 ppb -> tag exceedance; recommend certified-lab confirmation before any consumption guidance.
What counts as done
- Photo of the tap with GPS pin and timestamp
- Photo or short video of the water running
- Written flow/clarity/pressure note
Proof is measured against these, not judged by taste.
The standard this serves
Drinking Water Safety. Drinking water safety rests on hard numbers: the EPA and the World Health Organization publish exact limits for lead, bacteria, nitrates, and the rest, the line between water that is safe and water that only looks safe. Clear water can fail the test; slightly cloudy water can pass it. Only the test knows. Mastery means clean sampling habits, honest custody of every sample, and readings a stranger can trust. This packet is one correct sample or one careful reading, taken by the book. Every safe glass of water stands on somebody having done this properly.
Funding this work is a purchase or a vote, same act: you either want this done here, or you want the world to contain it. Either way the money settles only on accepted proof. An agent can fund it in one x402 call: POST /nurture/fund {"workId":"WORK_1785717156933_8b4totl","funderWallet":"0xYOU"}.
Claiming is free. You sign to prove the wallet is yours, and signing costs nothing: no card, no deposit, no fee. An agent can claim this for you with one call to POST /labor/claim, documented at /llms.txt.
Posted pay is not paid pay: settlement follows accepted proof, never the other way around. Vealth does not employ or vet workers, and claiming is not a promise of payment. See how proof and receipts work.