advanced work · Residential home, DuBois, PA
Is our basement air safe?, home radon test + mitigation-readiness plan, DuBois, PA.
Fund it for $360. Proof lands onchain when it's done.
$360 proposed
This packet is not funded yet, so this figure is a proposed price and not money waiting in escrow. If a buyer funds it, approved proof settles that price onchain. If nobody funds it, approved proof earns provable credit toward the work instead of cash — recorded, and readable any time at vealth.net/labor/credit/(your wallet). You see which before you claim, never after.
Claiming is free. You sign to prove the wallet is yours: no card, no deposit, no fee.
What the work involvesA family in DuBois, PA has never tested their home for radon despite living in a documented high-radon zone and wants to know whether the air where their kids sleep and play is safe.
How this work is done
A documented method, so this packet comes out the same whoever does it.
Bring
- EPA-listed radon test device (short-term charcoal / alpha-track kit or a continuous radon monitor)
- camera
- tablet/clipboard with the EPA radon protocol + 4 pCi/L action-level reference + NRPP/NRSB certified-professional lookup
- flashlight (foundation, sump, crawlspace, service penetrations)
- tape measure (test-placement height + foundation/entry-pathway mapping)
Steps
- 1. Sit with the household first: what prompted the concern (a neighbor's result, a basement bedroom/playroom, a real-estate transaction, a known Zone 1 county)? Who spends time on the lowest lived-in level and how many hours, children, sleeping areas, and any smokers (radon + smoking multiplies lung-cancer risk)? Record any prior test and its placement. Capture their concerns in their own words.
- 2. Map and photograph the foundation and the lowest lived-in level: slab / crawlspace / full or walk-out basement, sump pit, drain tile, floor and wall cracks, and service penetrations, the soil-gas entry pathways a mitigation system would address.
- 3. Guide correct placement of the EPA-protocol test: lowest lived-in level, ≥20 in. above the floor, ≥3 ft from exterior walls/windows/doors, away from drafts, heat, and humidity; NEVER in a kitchen, bathroom, or laundry. For a short-term test, establish closed-house conditions (windows/exterior doors shut, normal HVAC) 12 hours before and throughout. Record the device type, start time, and duration.
- 4. Record the radon result in pCi/L and interpret it against the EPA 4 pCi/L action level. If the result is at or above 4 pCi/L, note that the EPA recommends a confirming follow-up (a second short-term test or a long-term test) before committing to a permanent system; if a continuous monitor was used, note the hourly variability.
- 5. Where mitigation is warranted, scope a sub-slab depressurization readiness plan as a spec for a certified installer, candidate suction-point location, sump/drain-tile tie-in, fan location and vent-stack routing above the eave/roofline, electrical availability, and the required post-mitigation re-test. This is a scope, NOT an installation; no drilling, sealing, or fan is fitted.
- 6. Assemble the plan with the household: the current radon picture, whether action is warranted, the mitigation scope with a rough cost band, and the NRPP/NRSB-certified-professional path. Note interim risk-reduction steps (increase ventilation, avoid using the lowest level as a bedroom for vulnerable occupants) for the window before mitigation.
- 7. Review the plan WITH the household so they own the result and the next step; enter photos, GPS/address, test placement + type + result, the action-level interpretation, and the mitigation-readiness plan; sign. The family's claim of safe air = this plan + this evidence, Real (tested and mapped), Proven (photo + GPS + result + signature), One-of-one (this home, this foundation, this occupancy).
What counts as done
- Household's radon concerns recorded in their own words + who uses the lowest lived-in level and how many hours
- Foundation type + radon entry pathways photographed (slab/crawl/basement, sump, drain tile, floor and wall cracks, service penetrations)
- EPA-protocol test placement documented: lowest lived-in level, ≥20 in. off the floor, ≥3 ft from exterior walls/windows/doors, closed-house conditions, start time; test type + duration recorded
- Radon result in pCi/L recorded and interpreted against the EPA 4 pCi/L action level
- GPS / address confirm
- Mitigation-readiness plan where warranted: candidate suction-point location, sump/drain-tile tie-in, fan + vent-stack routing above the eave, required post-mitigation re-test, NRPP/NRSB-certified installer path, OR a documented below-action-level retest-interval recommendation
Proof is measured against these, not judged by taste.
What is promised, and what is not.
Funding this work is a purchase or a vote, same act: you either want this done here, or you want the world to contain it. A vote is free and signed; funding starts at one cent and anything beyond the wage is recorded as a premium for the worker. Either way the money settles only on accepted proof. An agent can fund it in one x402 call: POST /nurture/fund {"workId":"WORK_1788165190627_ub9db8c","funderWallet":"0xYOU"}.