← Board

the 4400-4500 block of Clara St, Cudahy, CA 90201

Install low-flow fixtures.

Replace this unit's standard-flow fixtures on the Clara St block in Cudahy, CA with WaterSense-rated aerators and showerheads. Read all of it

Not funded yet. Settles as earned credit, $95 proposed.

Proof it takes, the deadline, the level
  • Prooflandlord-permission record + before/after photos + flow-rate measurement + WaterSense label photo + GPS
  • Open until2026-12-10
  • Levelintermediate
All of it: the words, the place, the proof

Replace this unit's standard-flow fixtures on the Clara St block in Cudahy, CA with WaterSense-rated aerators and showerheads. That cuts the tenant's water bill without changing how the household uses water or requiring any lease-altering work.

Offer to pay $95. The receipt lands onchain once the proof is approved.

What it looks like
A worker shuts off the supply valve and replaces a standard showerhead with a WaterSense low-flow showerhead at the 4400-4500 block of Clara St, then photographs the installed fixture with a camera.

A description of this kind of work, not a record that it happened here.

Where
the 4400-4500 block of Clara St, Cudahy, CA 90201. Open the map
Pay
$95 proposed

This job is not funded yet, so this figure is a proposed price, not money held for the worker. If a buyer funds it, approved proof settles that price onchain. If nobody funds it, approved proof earns provable credit toward the work instead of cash: recorded, and readable any time at vealth.net/labor/credit/(your wallet). You see which before you claim, never after.

Proof
landlord-permission record + before/after photos + flow-rate measurement + WaterSense label photo + GPS

This is exactly what gets it approved. Nothing settles without it.

Level
intermediate
Open until
2026-12-10
Posted by
0x034F…6c89

The creator wallet. Its signature is what approves proof and settles the wage.

Safety, read before you claim

Start after the crew's safety orientation. Close the fixture's own supply stop before opening it where one is in reach and turns freely (a showerhead is swapped with the shower valve off), and never turn a building main, meter, backflow-prevention or fire-line fitting or force a stop that weeps or will not close. Aerators and showerheads only, in nitrile gloves and eye protection, with cold water for flow tests; a toilet or any pipe or valve work is licensed plumbing, so stop and tell the owner; wear slip-resistant closed-toe shoes.

The full safety list for this job:

  • Follow the manufacturer's installation instructions, and start only after the tenant AND the landlord or property manager consent.
  • Shut off the supply valve before removing any fixture, and do not modify the building's main shutoff or meter.
  • Old multi-turn stops often leak the first time they move in years: if one weeps, close the handle, stop, and report it to the owner. A showerhead has no supply valve of its own, so do not hunt for one; keep water from being pushed at the face. Test flow with cold water; hot lines scald and the water heater setting is the owner's. A swap says nothing about water quality, lead in old brass, or the pipes behind the wall; never call the water fit to drink. Wrap chrome in cloth or tape before gripping with a wrench. Hand every old part back to the owner in a bag.
  • Orientation to the site's injury and illness plan before touching a fixture: who to call, where first aid is, what to stop for (Title 8 section 3203).
  • Restrooms and closets run hot: water, a cool place to rest, watch each other for heat signs (use the outdoor heat plan, section 3395, for hose bibs and exterior fixtures) (Title 8 section 3396).
  • Eye protection under a sink or overhead at a shower arm: scale and debris fall in the face (Title 8 section 3382).
  • Wear gloves and closed-toe shoes (Title 8 section 3384).
  • Footwear, Title 8 section 3385: slip-resistant closed-toe shoes for wet floors and dropped fixtures.
  • Outdoors: wildfire smoke, section 5141.1: at a PM2.5 AQI of 151 or more the employer provides N95 respirators for voluntary use and moves the work indoors or cuts exposure where feasible; above AQI 500 respirators are required under a respiratory protection program.
  • Outdoors: heat, section 3395: drinking water, shade and cool-down rests; shade is ready at 80 F and the high-heat steps start at 95 F.
How this work is done

How this work is done

A documented method, so this packet comes out the same whoever does it.

Bring

  • bucket or flow bag marked in gallons and a phone timer
  • cloth or masking tape to protect chrome
  • eye protection
  • aerator key for tamper-resistant aerators
  • a bag for old parts

Steps

  1. Get the owner or manager's written consent and the building and room list before anything else (a block title is not a building). Then locate each old aerator or showerhead this job targets at the site its title names.
  2. Get the tenant's and the landlord's or property manager's permission for the fixture swap and record it.
  3. Photograph each existing fixture targeted for replacement, noting any flow rate printed on it.
  4. With the old fixture still running, run cold water into a marked bucket or bag for a timed 10 or 15 seconds and write down the volume and the seconds, so the gallons per minute can be recomputed from your numbers.
  5. Aerator: close the faucet and use its own stop only if it turns freely. Showerhead: shower valve off, no stop at all. Never go find a unit or building valve.
  6. Install aerators and showerheads only, chosen to meet California's limits as well as the WaterSense label (showerheads 1.8 gpm, residential lavatory faucets 1.2 gpm, public restroom lavatory faucets 0.5 gpm; verify the current CALGreen and Title 20 figures). Toilets move to a licensed plumber.
  7. Photograph the WaterSense label or model marking on each installed fixture.
  8. Turn the supply valve back on and check the connection for leaks.
  9. Leave toilets, flush valves and any pipe or valve work to the licensed plumber. If you find a running toilet on the walk, report it to the owner; do not repair it.
  10. Photograph each installed fixture.
  11. Measure the flow rate at each installed fixture and confirm it meets the WaterSense-rated maximum.

What counts as done

  • Written or recorded landlord/property-manager permission for the fixture swap
  • Before photo of each existing fixture with its flow rate noted where labeled
  • WaterSense-rated replacement label/model photo
  • After photo of each installed fixture
  • Flow-rate measurement confirming the WaterSense-rated maximum after install
  • The owner's or manager's consent, on the record.
  • The room for each fixture.
  • The timed bucket reading (gallons and seconds) before and after each fixture; a list of gpm numbers alone cannot be checked.
  • Photo of the old part in hand beside the new part's label.

Proof is measured against these, not judged by taste.

The standard this serves

Water Efficiency. Water efficiency is the quiet discipline of wasting nothing indoors. The EPA's WaterSense program sets the marks: how many gallons a minute a faucet should pass, how to find the leak that runs a toilet all night, how a household's water bill tells a story. Mastery looks like an auditor who can walk a home in an hour and find every hidden gallon. The skill is built one fixture at a time, which is exactly what this packet asks: measure one flow, find one leak, record one truth about where the water goes.

What is promised, and what is not

Three separate acts, never one: a vote is a free signed preference that moves no money; a pledge is free signed backing intent, balance-checked, that moves no money and never marks the packet funded; funding is a real payment, made by the payer straight to the worker, with no Vealth fee. Paying Vealth is closed: Vealth takes no new card or wallet payment for a job. To fund a job, offer to pay the worker directly, then pay them yourself when you accept the proof, from your own wallet or by your own card or bank. From a wallet: prepare_token_offer, sign, submit_token_offer; after the proof is accepted you pay the worker on chain and the worker records it (prepare_token_settlement, or POST /labor/settle for USDC on Base). By card or bank: prepare_direct_offer, sign, submit_direct_offer; you pay the worker yourself and the worker records it with prepare_direct_settlement. Both are free, need no gas, and move no money through Vealth.

Claiming is free. You sign to prove the wallet is yours: no card, no deposit, no fee. Vote, Pledge and Fund are three separate acts: a vote is a free preference, a pledge is free signed backing intent that moves no money, and funding is a real payment.

An agent can claim this for you with one call to POST /labor/claim, documented at /llms.txt.

Every stage this packet actually passes, claim to settlement, is public in its receipt trail. A stage that has not happened is not claimed.

Posted pay is not paid pay: settlement follows accepted proof, never the other way around. Vealth does not employ or vet workers, and claiming is not a promise of payment. See how proof and receipts work.

Other acts: vote, pledge, fund

Packet WORK_1794291534456_ly86l1e