intermediate work · Historic downtown building, Nevada City, CA 95959

Repair the soffit vent screens on a historic Nevada City building

Nevada City's downtown carries some of the oldest wood-frame buildings in the Sierra foothills, many with original eave soffit vents whose screens have rusted through or torn loose over the decades. Repairing those screens keeps embers and pests out of a building the town has kept standing since the Gold Rush. Standard: IBHS FORTIFIED vent protection standard + SDG 11 Proof: Photo of each repaired soffit vent screen Method (IBHS FORTIFIED vent protection standard + SDG 11): 1. Get building-owner permission and identify each soffit vent needing repair. 2. Set up a stabilized ladder appropriate for eave-height reach. 3. Remove the damaged screen material from each vent frame. 4. Fit and fasten new corrosion-resistant screen material to each vent. 5. Check each repaired screen sits flush with no gaps. 6. Photograph each repaired vent. Done when: Photo of each repaired soffit vent screen

Where
Historic downtown building, Nevada City, CA 95959
Pay
$75 proposed

This packet is not funded yet, so this figure is a proposed price and not money waiting in escrow. If a buyer funds it, approved proof settles that price onchain. If nobody funds it, approved proof earns provable credit toward the work instead of cash. You see which before you claim, never after.

Proof
Photo of each repaired soffit vent screen

This is exactly what gets it approved. Nothing settles without it.

Level
intermediate
Open until
2026-09-16

How this work is done

A documented method, so this packet comes out the same whoever does it. Typically 45–240 minutes. Method of record: IBHS FORTIFIED Home (TM) wind-mitigation retrofit family -- opening protection (storm shutters), soffit/vent hardening, garage-door bracing, and roof-to-wall/gable-end structural connectors for hurricane-prone housing. IBHS FORTIFIED Home Standards (Roof/Silver/Gold) + ICC-600. Ground-level, spotted-stepladder (6 ft max) or attic-hatch access only for entry/intermediate rungs; structural connector work (roof-to-wall straps, gable-end bracing) is licensed/permitted, advanced-only.

Bring

Steps

  1. 1. Photograph the specific hardening item (opening, soffit vent, garage door, or attic connection) as found, and confirm the manufacturer/engineered spec (and permit, for structural connector work) for the measure being installed.
  2. 2. Confirm owner/occupant consent and scope; for any roof-to-wall strap or gable-end bracing work, confirm the permit and licensed-contractor assignment before starting.
  3. 3. Install or repair the specific FORTIFIED hardening measure per its manufacturer/engineered spec, working from ground level, a spotted stepladder (6 ft max), or the attic hatch/decking only -- never the roof edge.
  4. 4. Verify the installed measure meets its FORTIFIED/ICC-600 spec (seated panel, secured bracing, rated connector) and photograph the finished work from the same vantage as the before photos.
  5. 5. Record the hardening item completed, materials/connector spec used, and any permit/inspection reference into the proof record; sign.

If it does not match the plan

What counts as done

Proof is measured against these, not judged by taste.

Claim it on the board

Claiming is free. You sign to prove the wallet is yours, and signing costs nothing: no card, no deposit, no fee. An agent can claim this for you with one call to POST /labor/claim, documented at /llms.txt.

Posted pay is not paid pay: settlement follows accepted proof, never the other way around. Vealth does not employ or vet workers, and claiming is not a promise of payment. See how proof and receipts work.