Anyone can start here · Host-invited homes near Josephine Ave & Oregon Ave, Corcoran, CA 93212
Swap swamp-cooler pads before summer at invited Corcoran homes (2026-07-19)
Corcoran cools on evaporative coolers, and worn mineral-caked pads mean weak cooling and wasted water through the hottest weeks. A pre-season swap at invited homes — pads, basin scrub, wetting check — restores cooling for the cost of pads. Ground-set and reachable window units only keep it safe for anyone. Standard: Manufacturer evaporative-cooler seasonal service practice; SDG 7 Affordable and Clean Energy. Proof: Photos of pads, basin, running unit with GPS/date Method (Manufacturer evaporative-cooler seasonal service practice; SDG 7 Affordable and Clean Energy.): 1. Unplug the unit and confirm it is ground-set or safely reachable. 2. Remove panels, pull spent pads, and scrub scale from frames and basin. 3. Fit new pads, reassemble, refill, and restore power. 4. Run the pump and confirm even wetting and strong airflow. 5. Photograph old pads, cleaned basin, and running unit, and record with GPS and date. Done when: Photos of pads, basin, running unit with GPS/date
How this work is done
A documented method, so this packet comes out the same whoever does it. Typically 60–120 minutes. Method of record: ASHRAE Level 1 energy audit
Bring
- tablet/clipboard
- tape measure
- light meter (lighting scope)
- clamp thermometer (refrigeration scope)
- 12-month utility bills
- camera
- ladder + spotter (high fixtures)
Steps
- 1. Confirm the address; arrange a staff escort for mechanical/back-of-house.
- 2. Photograph HVAC, lighting, envelope, and any in-scope systems.
- 3. Inventory systems: HVAC type + age; lighting fixture count/type/wattage; refrigeration units; envelope condition.
- 4. Summarize 12 months of utility use (kWh / therms) from the bills.
- 5. Take the in-scope measurements (light levels, unit temperatures, seal condition).
- 6. Rank no-cost/low-cost measures, then capital measures, with rough savings logic.
- 7. Enter inventory, measurements, utility summary, photos, and the ranked measure list; sign.
If it does not match the plan
- Knob-and-tube, ungrounded or overheated wiring, scorched outlets, or a hot electrical panel -> STOP: do not operate the circuit; route to a licensed electrician and restrict use (NEC / fire hazard).
- Gas odor, or a combustion appliance with absent/blocked venting (backdrafting / CO risk) -> STOP: evacuate, ventilate, call the gas utility. The agent escalates, never relights or adjusts gas.
- Any live-electrical/gas hazard -> document, do not touch, flag for a licensed pro.
- Refrigeration unit out of food-safe range -> flag as both energy and food-safety risk.
- Suspected asbestos/lead in materials -> flag and stop.
What counts as done
- System inventory complete for the in-scope equipment
- 12-month utility use summary recorded
- In-scope measurements recorded with units
- Ranked no-cost/low-cost + capital measure list produced
Proof is measured against these, not judged by taste.