intermediate work · Downtown Placerville home attic, Placerville, CA 95667

Add attic insulation to an older downtown Placerville home

Downtown Placerville's older homes were built long before modern insulation standards, and their thin attic insulation lets Sierra foothill winter cold sink straight into the living space. A insulation top-up in an invited attic cuts the heating bill through the coldest months. Standard: DOE Weatherization Assistance Program attic insulation standard + SDG 7 Proof: Before/after photo of insulation depth with tape measure Method (DOE Weatherization Assistance Program attic insulation standard + SDG 7): 1. Get the resident's invitation and confirm the attic access point. 2. Measure the existing insulation depth at several points across the attic. 3. Lay batts or blow loose-fill insulation to bring the attic to the recommended R-value. 4. Keep insulation clear of recessed light fixtures and vents per manufacturer spacing. 5. Photograph the insulation depth before and after with a tape measure visible. 6. Confirm attic access is left clear and safe on exit. Done when: Before/after photo of insulation depth with tape measure

Where
Downtown Placerville home attic, Placerville, CA 95667
Pay
$380 proposed

This packet is not funded yet, so this figure is a proposed price and not money waiting in escrow. If a buyer funds it, approved proof settles that price onchain. If nobody funds it, approved proof earns provable credit toward the work instead of cash. You see which before you claim, never after.

Proof
Before/after photo of insulation depth with tape measure

This is exactly what gets it approved. Nothing settles without it.

Level
intermediate
Open until
2026-09-18

How this work is done

A documented method, so this packet comes out the same whoever does it. Typically 90–240 minutes. Method of record: Ohio Development Services Agency Home Weatherization Assistance Program (HWAP) — the state pass-through of the DOE Weatherization Assistance Program's cold-climate field protocol: blower-door-directed air sealing toward a CFM50 infiltration target, attic insulation to R-49 / wall cavity to R-13, and mandatory pre/post combustion-safety testing before any tightening closes out.

Bring

Steps

  1. 1. Walk the home with the occupant, note every combustion appliance present, and photograph each nameplate before any work begins.
  2. 2. Set up the calibrated blower door in the main entry and record the baseline CFM50 reading.
  3. 3. Trace and photograph the top infiltration paths with a smoke pencil (rim joist, attic hatch, penetrations, window/door perimeters).
  4. 4. Run the pre-tightening combustion-safety check (ambient CO reading, spillage test at draft hoods) with the blower door off; a failed check stops the job and routes to a licensed HVAC technician before any sealing.
  5. 5. Air-seal the ranked leak paths in order and bring attic insulation to R-49 / accessible wall cavity to R-13 per the HWAP job sheet, maintaining required soffit-to-ridge ventilation.
  6. 6. Re-run the blower-door test to confirm the new CFM50 result.
  7. 7. Run the mandatory post-tightening combustion-safety re-test; a failed re-test stops the job and routes to a licensed HVAC technician for venting correction before further sealing.
  8. 8. Photograph the finished insulation depth and the passed post-tightening combustion-safety check; enter before/after CFM50, materials used, and the combustion-safety result into the proof record; sign.

If it does not match the plan

What counts as done

Proof is measured against these, not judged by taste.