Anyone can start here · Host-invited home, Govandi, Mumbai 400043
Swap the filter cartridge at the Govandi household on a quarterly cycle (2026-07-20)
A household filter needs its cartridge changed on schedule to keep working; a skipped swap quietly lets unsafe water back through. This visit keeps the previously installed Govandi filter performing to standard. Standard: WHO Guidelines for Drinking-water Quality (household water treatment) + SDG 6.1 safe drinking water. Proof: Photo of new cartridge + leak-free running-water test Method (WHO Guidelines for Drinking-water Quality (household water treatment) + SDG 6.1 safe drinking water.): 1. Confirm the household invitation and locate the installed filter unit. 2. Check the cartridge change indicator and flow rate. 3. Remove the old cartridge and install a fresh certified replacement. 4. Run water through the filter for five minutes and check for leaks. 5. Photograph the new cartridge and running-water test, with GPS and date, as proof. Done when: Photo of new cartridge + leak-free running-water test
How this work is done
A documented method, so this packet comes out the same whoever does it. Typically 30–60 minutes. Method of record: EPA drinking-water sampling (3Ts / LCR first-draw where lead is in scope)
Bring
- GPS-capable phone
- test kit for each named analyte (nitrate/coliform/arsenic/lead as specified)
- clean sample bottle + label
- nitrile gloves
- camera
Steps
- 1. Navigate to the sampling point; confirm GPS is inside the posting radius; record the waypoint.
- 2. Photograph the tap or wellhead with a legible timestamp.
- 3. If first-draw is required, sample after >=6h stagnation; if flushed, run the tap 2-3 minutes first, then sample.
- 4. Fill the bottle without touching the inside; cap immediately.
- 5. Run each test per kit instructions; wait the exact develop/incubation time; read and record every value with units.
- 6. Record coliform as present/absent after the stated incubation window.
- 7. Enter all readings, units, GPS, time, and photos into the proof record; sign it.
If it does not match the plan
- Nitrate > 10 mg/L -> tag 'exceeds EPA MCL'; advise no infant consumption pending certified-lab confirmation.
- Total coliform present -> advise disinfection + retest; recommend lab confirmation.
- Arsenic > 10 ppb or Lead > 15 ppb -> tag exceedance; recommend certified-lab confirmation before any consumption guidance.
What counts as done
- GPS waypoint recorded inside the posting radius
- Timestamped photo of the exact sampling point
- Each required analyte recorded with a numeric value + units (or present/absent)
- Sampling type (first-draw vs flushed) explicitly noted
Proof is measured against these, not judged by taste.
Claiming is free. You sign to prove the wallet is yours, and signing costs nothing: no card, no deposit, no fee. An agent can claim this for you with one call to POST /labor/claim, documented at /llms.txt.
Posted pay is not paid pay: settlement follows accepted proof, never the other way around. Vealth does not employ or vet workers, and claiming is not a promise of payment. See how proof and receipts work.