Anyone can start here · Flat residential lot, Quincy, CA 95971

Hand-clear the debris flagged in the Quincy flat-lot ignition-zone survey (2026-07-19)

The ignition-zone survey at this flat-lot Quincy home flagged dry pine needle litter banked against the foundation on level ground, the kind of easy fuel that closes the safety gap fastest. Hand-clearing it now, entirely on flat yard, keeps that margin wide. Standard: CAL FIRE defensible space zone 0 clearing standard + SDG 11 Proof: Before/after photo of the cleared 5-ft zone Method (CAL FIRE defensible space zone 0 clearing standard + SDG 11): 1. Bring the ranked survey list to the site. 2. Rake dry pine needles and leaf litter out of the first 5 feet around the home by hand. 3. Relocate any woodpile at least 30 feet from the structure on the level lot. 4. Clear dry, dead plant material from under decks and against walls by hand. 5. Bag or stack cleared debris for pickup away from the structure. 6. Photograph the cleared zone next to the survey's before photo. Done when: Before/after photo of the cleared 5-ft zone

Where
Flat residential lot, Quincy, CA 95971
Pay
$220 proposed

This packet is not funded yet, so this figure is a proposed price and not money waiting in escrow. If a buyer funds it, approved proof settles that price onchain. If nobody funds it, approved proof earns provable credit toward the work instead of cash. You see which before you claim, never after.

Proof
Before/after photo of the cleared 5-ft zone

This is exactly what gets it approved. Nothing settles without it.

Level
entry
Open until
2026-10-19

How this work is done

A documented method, so this packet comes out the same whoever does it. Typically 45โ€“90 minutes. Method of record: NFPA 1144 / Firewise USA structure-ignition-zone defensible-space assessment โ€” documentation-only from a safe public/yard vantage

Bring

Steps

  1. 1. Document only โ€” photograph Zone 0 (0-5 ft from the structure), Zone 1 (5-30 ft) and Zone 2 (30-100 ft) from the driveway or yard edge; never enter dense brush or approach a structurally questionable outbuilding.
  2. 2. Note vegetation type, spacing and ladder-fuel presence (brush touching tree canopy) in each zone from the safe vantage.
  3. 3. Photograph the roof material, gutters, vents, and any firewood or combustible material stacked against the structure.
  4. 4. Compile the zone-by-zone findings into a defensible-space checklist naming what a licensed/credentialed vegetation-management crew should clear first; never clear, cut, or move anything during this survey.

If it does not match the plan

What counts as done

Proof is measured against these, not judged by taste.

Claim it on the board

Claiming is free. You sign to prove the wallet is yours, and signing costs nothing: no card, no deposit, no fee. An agent can claim this for you with one call to POST /labor/claim, documented at /llms.txt.

Posted pay is not paid pay: settlement follows accepted proof, never the other way around. Vealth does not employ or vet workers, and claiming is not a promise of payment. See how proof and receipts work.