Anyone can start here · Invited household, Burns Creek settlement, Honiara, Solomon Islands
Swap the filter cartridge on a serviced Burns Creek household unit (2026-07-20)
A saturated cartridge stops protecting a household quietly, and replacement is easy to postpone on a tight budget. A scheduled swap keeps the unit actually working. Standard: WHO Guidelines for Drinking-water Quality; SDG 6.1 (safe and affordable drinking water). Proof: Cartridge swap photo + updated record Method (WHO Guidelines for Drinking-water Quality; SDG 6.1 (safe and affordable drinking water).): 1. Confirm the household and locate the unit from the install record. 2. Remove the spent cartridge and inspect the housing. 3. Insert the new certified cartridge and flush per instructions. 4. Test output flow and check for leaks. 5. Photograph the new cartridge date sticker and update the household record. Done when: Cartridge swap photo + updated record
How this work is done
A documented method, so this packet comes out the same whoever does it. Typically 30–60 minutes. Method of record: EPA drinking-water sampling (3Ts / LCR first-draw where lead is in scope)
Bring
- GPS-capable phone
- test kit for each named analyte (nitrate/coliform/arsenic/lead as specified)
- clean sample bottle + label
- nitrile gloves
- camera
Steps
- 1. Navigate to the sampling point; confirm GPS is inside the posting radius; record the waypoint.
- 2. Photograph the tap or wellhead with a legible timestamp.
- 3. If first-draw is required, sample after >=6h stagnation; if flushed, run the tap 2-3 minutes first, then sample.
- 4. Fill the bottle without touching the inside; cap immediately.
- 5. Run each test per kit instructions; wait the exact develop/incubation time; read and record every value with units.
- 6. Record coliform as present/absent after the stated incubation window.
- 7. Enter all readings, units, GPS, time, and photos into the proof record; sign it.
If it does not match the plan
- Nitrate > 10 mg/L -> tag 'exceeds EPA MCL'; advise no infant consumption pending certified-lab confirmation.
- Total coliform present -> advise disinfection + retest; recommend lab confirmation.
- Arsenic > 10 ppb or Lead > 15 ppb -> tag exceedance; recommend certified-lab confirmation before any consumption guidance.
What counts as done
- GPS waypoint recorded inside the posting radius
- Timestamped photo of the exact sampling point
- Each required analyte recorded with a numeric value + units (or present/absent)
- Sampling type (first-draw vs flushed) explicitly noted
Proof is measured against these, not judged by taste.
Claiming is free. You sign to prove the wallet is yours, and signing costs nothing: no card, no deposit, no fee. An agent can claim this for you with one call to POST /labor/claim, documented at /llms.txt.
Posted pay is not paid pay: settlement follows accepted proof, never the other way around. Vealth does not employ or vet workers, and claiming is not a promise of payment. See how proof and receipts work.